XS1M18MA230 SQUARE D, XS1M18MA230 Datasheet - Page 53

Inductive Proximity Sensor

XS1M18MA230

Manufacturer Part Number
XS1M18MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Wiring
For additional cable options and lengths see p. 518
Accessories. . . . . . . . . . . . . . . . . . . . . page 298, 316
10/02
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Connector
4
1
4 wire NO + NC
Wire color/connector pin
3 wire NO or NC
PNP
NPN
PNP
NPN
3
2
7427
XSZB1
BN/1
BU/3
BN/1
BU/3
BN/1
BU/3
BN/1
BU/3
NO
NO
NC
NC
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
kk
BK/4
WH/2
BK/4
WH/2
Cable
Blue
Brown
Black
9006PA
+
+
+
+
-
-
-
-
BU –
BN +
BK Output
kk
XS Tubular Inductive Sensors / 30 mm Diameter, DC; Economy Short Length
Specifications
Options
Accessories
a
Mechanical
Usable sensing rangea
Standard temperature range
Extended range
Enclosure rating - cable
(for connector, see p. 518)
Enclosure material
Tightening torque (max.)
Vibration resistance
Shock resistance
Standard target size (steel)
Differential (% of Sr)
Repeatability (% of Sr)
LED indicator type
Cable
Electrical
Voltage range
Voltage limit (including ripple)
Voltage drop (across switch), closed state
Maximum load current
Current consumption (no load)
On delay (max.)
Off delay (max.)
Power up delay
Protective circuitry
Agency Listings
Description
Extended temperature range
(cable type and standard sensing distance only)
Extended cable length
Description
Plastic mounting nuts
Metal mounting nuts and lock nuts
Mounting bracket 90° steel
Mounting bracket, plastic, long length
0.5" NPT conduit adapter length 2" (50.8mm)
Refer to p. 351 for target material correction coefficient Km.
©
1997-2002 Schneider Electric All Rights Reserved
Shielded
Non-shielded
Nickel plated brass
Plastic
Nickel plated brass
Plastic
Nickel plated brass
Plastic
Nickel plated brass
Plastic
(IEC 60068.2.6)
(IEC 60068.2.27)
Shielded
Unshielded
A
B
3 or 4 wire
Shielded
Non-shielded
Shielded
Non-shielded
Short circuit protection
Overload
Radio frequency immunity (RFI)
Electrostatic; transients; impulse
(L – indicates level number)
Reverse polarity protection
®
E 164869
CCN NRKH
30 mm Diameter, DC; Economy Short Length
Standard Range
Extended Range
NEMA Type
IEC Type
NEMA Type
IEC Type
Case
Sensing face
Case
Sensing face
Standard Range
Extended range
Standard Range
Extended Range
Standard Range
Extended Range
CR 44087
Class 3211 03
Aluminum
Down to -40° C (-40° F)
16.4 ft. (5 meter) cable
32.8 ft. (10 meter) cable
XS Tubular Inductive Sensors
0 to 8 mm
0 to 16 mm
0 to 12 mm
-25° C to +70° C (-13° F to +158° F)
-25° C to +80° C (-13° F to +176° F)
-25° C to 50° C (-13° F to +122° F)
3, 4X, 6P, 12, 13
IP67
3, 4X, 6P, 12, 13
IP68
Nickel plated brass
PBT
PBT
PBT
40 N•m 29.5 (lb-ft)
20 N•m 15 (lb-ft)
25 G, amplitude +/- 2 mm, f = 10-55 Hz
50 G duration 11 ms
1.18" x 1.18" (30 mm x 30 mm)
1.88" x 1.88" (48 mm x 48 mm)
1.41" x 1.41" (36 mm x 36 mm)
15%
3%
360° ring LED: Shows output status
One LED visible from 4 quadrants: Shows output
status
22 AWG (0.34 mm
12 to 24 Vdc
10 to 38 Vdc
2 V
200 mA
10 mA
0.3 ms
0.6 ms
0.3 ms
0.7 ms
1.4 ms
0.7 ms
5 ms
Yes
Yes
IEC 61000-4-3 Level 3
2 wire: IEC 61000-4-2 L3; IEC 61000-4-4 L2;
60947.5.2 L3
3 wire: IEC 61000-4-2 L3; IEC 61000-4-4L3;
60947.5.2 L3
Extended range: IEC 61000-4-4 L3
Yes
Proximity Sensors
2
), PvR
Catalog Number
XSZE230
XSZE130
9006PA30
XSZB130
7427
Suffix
TF
L1
L2
249

Related parts for XS1M18MA230