XS1M18MA230 SQUARE D, XS1M18MA230 Datasheet - Page 89

Inductive Proximity Sensor

XS1M18MA230

Manufacturer Part Number
XS1M18MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 298
Wiring
10/02
2 wire, AC/DC
3 wire, DC
PNP
Bu
XSZB130
Bn
7427
Bk
Bn
Bu
+
-
25 turn
Potentiometer
+/-
+/-
9006PA30
Cover
XSAV Tubular, Inductive Sensors / 30 mm Diameter, Motion Detection, DC or AC/DC
Specifications
a
Options
Ex: XSAV11373 TT L05
Accessories
Application Notes:
Mechanical
Usable sensing rangea
Standard temperature range
Enclosure rating
Vibration resistance
Shock resistance
Standard target size (steel)
Repeatability (% of Sr)
Differential (hysteresis)
Cable
Electrical
Voltage drop (across switch) max.
Inrush current (inductive @ 20 ms)
Minimum load current
Current Consumption (no load)
Start-up delay (max.)
Agency Listings
Description
Extended temperature range
5 meter cable length
10 meter cable length
Description
Metal locknuts (1 pair included)
Mounting bracket, 90° steel
Mounting bracket, plastic
0.5" NPT conduit adapter
The number of targets is determined knowing that the actual number of pulses per minute n, is n=mN where m is the number of targets
and N the speed in rpm.
This number (n) should be within the operating frequency range given in the selection table. For reasons of mechanical balance,
even numbers are recommended (2, 4, 6 etc.).
Frequency threshold adjustment:
As long as the speed (number of pulses/min.) is above the threshold level – adjustable via 25 turn potentiometer within the threshold range
– the output circuit assumes its closed state. When the actual speed falls below the threshold level, the output circuit assumes its open
state. To preserve the start-up delay, the switch should be reset by removing and reapplying the power supply.
When the line voltage is initially applied, the output automatically assumes its closed state for the duration of the start-up delay. This allows
the mechanical assembly to overcome inertia and reach its nominal speed, greatly simplifying the interlocking circuit. After the start-up
delay, the switch will perform as described above.
Care should be taken not to exceed the maximum frequency rating above which the sensor cannot detect the target, therefore, assuming
zero speed condition.
(only one option per device)
1/Fr in the start up delay formula is the actual preset frequency adjusted via potentiometer. (1/Fr is not significant if threshold is above
60 pulses/min.).
Refer to page 351 for target material correction coefficient Km.
©
1997-2002 Schneider Electric All Rights Reserved
30mm Diameter, Motion Detection, DC or AC/DC
0.7" (18 mm)
1.18" (30 mm)
NEMA Type
IEC Type
0.7" (18mm) diameter
1.18" (30mm) diameter
PvR
XSAV1 models
XSAV3 models
XSAV0 models
to +185° F (+85° C)
to -40° F (-40° C)
XSAV Tubular, Inductive Sensors
0-0.15" (0-4 mm)
0--.31" (0-8 mm)
-13° F to +158° C (-25° F to +70° F)
1, 3, 4, 6, 12, 13
IP67
25 G, amplitude ± 2 mm, f =10-55 Hz
50 G duration 11 ms
0.7" x 0.7" (18mm x 18mm)
1.18" x 1.18" (30mm x 30mm)
3%
20 AWG
AC/DC
5.7 V
2 A
5 mA
9 sec. ±20% + 1/Fr ➀
3 sec. ±20% + 1/Fr ➀
0 sec.
5-15% of pre-set frequency
Proximity Sensors
Suffix
TT
TF
L05
L10
Catalog Number
XSZE130
9006PA30
XSZB130
7427
15 mA
DC
1.8 Vdc
285

Related parts for XS1M18MA230