E3X-DAC-S
Do not use the product in atmospheres or environments that
exceed product ratings.
Amplifier Unit
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power
supply is turned ON. If the Sensor and load are connected to
separate power supplies, be sure to turn ON the Sensor first.
Time may be required for the incident level to stabilize after
the power supply is turned ON.
Operation When Turning Power OFF
Output pulses may occur when the power is turned OFF. Turn
OFF the power supply to the load and the load line before
turning OFF the power supply to the Sensor.
● Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
2. Attach the protector seals (provided as accessories) to the
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is
2. After the Amplifier Unit(s) has been separated, press down
until it clicks into place.
sides of master and slave connectors that are not connect-
ed.
to be removed away from the rest of the group.
on the lever on the Connector and remove it. (Do not at-
tempt to remove Connectors without separating them from
other Amplifier Units first.)
Precautions for Correct Use
Seal
Insert
Press down
Remove
Lever
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove Ampli-
fier Units from the DIN track without separating them first.)
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Am-
plifier Unit moving, e.g., due to vibration.
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection
of the Fiber Unit. Connect or disconnect the fibers using the
following procedures:
1. Connection
Open the protective cover, insert the fibers according to the
fiber insertion marks on the side of the Amplifier Unit, and low-
er the lock lever.
Lock button
Note:1. The specifications for ambient temperature will vary according to the
Note: Do not pull on, compress, or otherwise exert excessive force on the fi-
press the Amplifier Units together until they click into place.
Fiber
2. Always turn OFF the power supply before joining or separating Ampli-
bers after connecting them to the Amplifier Unit. (Do not exert more
than 0.3 N·m.)
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
fier Units.
Fiber insertion mark
Locked
End Plate
9 mm
Unlocked
Insertion position
Protective cover
Click into place