E32-TC200E Omron, E32-TC200E Datasheet - Page 19

no-image

E32-TC200E

Manufacturer Part Number
E32-TC200E
Description
FIBER OPTIC CABLE
Manufacturer
Omron
Type
General Purposer
Datasheets

Specifications of E32-TC200E

Rohs Compliant
YES
Fiber Optic Sensor Type
General Purpose
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1
2
Match ON
Mismatch ON
* Workpiece colors must always be taught to perform judgment for
* With the factory settings, 1-point teaching can be executed in RUN
* The threshold level can be changed if the teaching level function is
* If BLACK mode is selected as the judgment mode in SET mode, the
* Advanced Models
* Advanced Models
The operation mode is set with the Mode Selector.
2-1. One-point Teaching
Along with registering the workpiece colors, the threshold
can be set at approximately –10% of the match.
The setting is completed in a simple operation with one
press of a button.
Teaching with
Workpiece
The set condition
will flash twice.
Set the SET/RUN Mode
Selector to SET.
registered workpiece colors.
mode. (Press the MODE Key for 3 s.)
used in SET mode.
threshold will be set to a level of approximately 10% higher than the
displayed degree of matching.
The operation mode is set in SET mode.
Set the Channel Selector to the desired channel before making
any adjustments or settings. This is true for all adjustments and
settings.
Setting the Operation Mode
Registering Workpiece Colors with Teaching in SET Mode
SET
Page 20 Refer to 4. Setting Functions in SET Mode.
Operation mode
Workpiece
L-ON
D-ON
Match
Match
L
UP
Operation
RUN
DOWN
(Factory-set)
D
Threshold
Threshold
To RUN
either button
for 1 s.
Press
* When teaching is performed, position the workpiece by using the
3
* Even if the display method for the Display Switch Function is
2-2. Teaching with and without the Workpiece
Two points, with and without the workpiece, are
detected, and the match of the intermediate point is set
as the threshold value.
This method is ideal for setting thresholds with margins
or performing judgments with low match.
Teaching with
Workpiece
The set condition
will flash twice.
Teaching without
Workpiece
The set threshold
will flash twice.
OVER, OK, and LO messages displayed on the sub-display (green)
as guides.
A threshold can be set manually. A threshold value can
also be fine-tuned using manual setting after teaching.
Set the SET/RUN Mode
Selector to SET.
Set the SET/RUN Mode
Selector to SET.
changed, the threshold will appear on the sub-display when the key
is pressed.
(Factory-set to RUN)
Setting Thresholds Manually in RUN Mode
SET
RUN
Workpiece
Increases threshold.
OVER : Move the workpiece away.
OK
LO
Match
Match
Match
Match
: Teaching is possible.
: Move the workpiece closer.
E3X-DAC-S
UP
UP
UP
RUN
DOWN
Decreases threshold.
DOWN
DOWN
Threshold
Threshold
Threshold
Threshold
To RUN
either button
either button
for 1 s.
for 1 s.
Press
Press
19

Related parts for E32-TC200E