G3PE-215B DC12-24 Omron, G3PE-215B DC12-24 Datasheet

no-image

G3PE-215B DC12-24

Manufacturer Part Number
G3PE-215B DC12-24
Description
15A 1-phase SSR, Zero Cross
Manufacturer
Omron
Datasheet

Specifications of G3PE-215B DC12-24

Control Voltage Range
12 VDC to 24 VDC
Load Voltage Rating
240 V
Load Current Rating
15 A
Output Device
Triac
Mounting Style
DIN Rail
Relay Type
Solid State
Termination Style
DIN Rail
Control Voltage Type
AC
Load Current
15A
Relay Terminals
Screw
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Slim Profile Industrial SSR with Heatsink
ideal for heater applications.
• Snubber circuit provides excellent short-term surge
• 15A and 25A models have slim 22.5mm width.
• Zero cross or “fast turn on” models.
• DIN track or panel mounting possible.
• LED indicator standard on all single phase models.
• UL, CSA and TÜV approved
• RoHS compliant.
Ordering Information
■ List of Models
* The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in the Engineering
Single-phase
absorption.
Single-phase Solid State Relays for Heaters
G3PE
Data section.
Number of
phases
Refer to Safety Precautions
Phototriac
coupler
Isolation
method
.
Yes (yellow)
Operation
indicator
12 to 24 VDC
Rated input
Single-phase Solid State Relays for Heaters
voltage
Yes
No
Zero cross
function
15 A, 100 to 240 VAC G3PE-215B DC12-24
25 A, 100 to 240 VAC G3PE-225B DC12-24
35 A, 100 to 240 VAC G3PE-235B DC12-24
45 A, 100 to 240 VAC G3PE-245B DC12-24
15 A, 100 to 240 VAC G3PE-215BL DC12-24
25 A, 100 to 240 VAC G3PE-225BL DC12-24
35 A, 100 to 240 VAC G3PE-235BL DC12-24
45 A, 100 to 240 VAC G3PE-245BL DC12-24
Applicable load *
G3PE
Model
427

Related parts for G3PE-215B DC12-24

G3PE-215B DC12-24 Summary of contents

Page 1

... The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in the Engineering Data section. Rated input Zero cross Applicable load * voltage function 15 A, 100 to 240 VAC G3PE-215B DC12- 100 to 240 VAC G3PE-225B DC12-24 Yes 35 A, 100 to 240 VAC G3PE-235B DC12- 100 to 240 VAC G3PE-245B DC12- VDC 15 A, 100 to 240 VAC G3PE-215BL DC12-24 ...

Page 2

... Ratings Input (at an Ambient Temperature of 25°C) Item Rated voltage Model G3PE-@@@ VDC G3PE-@@@BL Output Model G3PE-215B(L) G3PE-225B(L) G3PE-235B(L) G3PE-245B(L) Item 100 to 240 VAC (50/60 Hz) Rated load voltage 75 to 264 VAC (50/60 Hz) Load voltage range 0 0 Applicable load current * (at 40°C) (at 40° ...

Page 3

... Energized time (ms) G3PE-2@@ 25° Input current Input impedance Input voltage (V) G3PE-235B(L), G3PE-245B( G3PE-245B(L) 40 G3PE-235B( −30 − 100 Ambient temperature (°C) G3PE-225B(L) 250 200 150 100 100 300 500 1,000 3,000 5,000 Energized time (ms) Single-phase Solid State Relays for Heaters ...

Page 4

... Approvals UL Recognized, CSA Certified and EN60947-4-3 (TÜV) approved 430 Single-phase Solid State Relays for Heaters G3PE-235B( Relays 3 Relays Relays 8 Relays −40 − 100 Ambient temperature (°C) Ambient temperature (°C) G3PE G3PE-245B( Relays Relays −40 − 100 100 Ambient temperature (°C) ...

Page 5

... Two, M3.5 4.6 × 5.6 elliptical hole 44.5 max. Note: With terminal cover. (100) (90) (85) Single-phase Solid State Relays for Heaters 4.5 G3PE-2@@B (+) (+) − ( − Terminal Arrangement/Internal Circuit Diagram G3PE-5@@B G3PE-2@@B (+) (+) − ( − G3PE 431 ...

Page 6

... Do not use the G3PE with loose terminal screws. Otherwise, excessive heat generated by the wire may cause burning. • For the G3PE models with a carry current larger, use M5 crimp terminals that are an appropriate size for the diameter of the wire. ...

Page 7

... It will be necessary to provide the above conditions as well as the load conditions if the user wants to confirm the ratings of specific SSRs. Causes of Failure • Do not drop the G3PE or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. • Tighten each terminal to the torque specified below. Improper tightening may result in abnormal heat generation at the terminal, which may cause burning ...

Page 8

... Confirm that turning the output ON for a half cycle will not cause a problem for the device or system in which the G3PE is being used prior to actual use. The G3PE malfunction withstand limit is shown below. • Malfunction withstand limit (reference value): 500 V Note: This value was measured under the following conditions. Noise duration: 100 ns and 1 μ ...

Page 9

... A Required number of 0.23 0.39 fans per SSR Example: For 10 G3PE SSRs with load currents 0.23 × 2.3 Thus, 3 fans would be required. Note: 1. Size of fans × 92 mm, Air volume: 0.7 m Ambient temperature of control panel: 30° there are other instruments that generate heat in the control panel in addition to SSRs, more ventilation will be re- quired ...

Page 10

... MEMO 436 Single-phase Solid State Relays for Heaters G3PE ...

Page 11

... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Single-phase Solid State Relays for Heaters G3PE ...

Page 12

... European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Specifications subject to change without notice G3PE Printed in USA ...

Related keywords