CS1W-AD081-V1 Omron, CS1W-AD081-V1 Datasheet - Page 17

no-image

CS1W-AD081-V1

Manufacturer Part Number
CS1W-AD081-V1
Description
MODULE, ANALOG IN, 8CH
Manufacturer
Omron
Datasheet

Specifications of CS1W-AD081-V1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Function Blocks (Unit Ver. 3.0)
Node Terminal Blocks
CPU Unit Terminal Blocks
SCADA Interface Blocks
Note: 1. Node Terminal Blocks, CPU Unit Terminal Blocks, and SCADA Interface Blocks are supported by the CS1W-LC001 only.
Send to Computer
Send to All Nodes
Receive from All
Nodes
CPU Unit Terminals
Expanded CPU Unit
Terminals
Send/
Receive All Blocks
22
2. The CS1@-LCB@@@ supports User Link Tables and an HMI instead.
Type
Type
Type
DO to Computer
AO to Computer
1-Block Send Terminal to
Computer
4-Block Send Terminal to
Computer
DO Terminal to All Nodes
AO Terminal to All Nodes
DO Terminal Settings from
Computer
AO Terminal Settings from
Computer
DI Terminal from All Nodes Receives 32 contacts sent from nodes on the Controller Link Data Link.
AI Terminal from All Nodes Receives 2 analog values sent from nodes on the Controller Link Data Link.
DI Terminal from CPU Unit Inputs max. 128 points from any leading address in CPU Unit I/O memory (one of CIO, WR,
DO Terminal to CPU Unit
AI Terminal from CPU Unit Inputs max. 8 words from any leading address in CPU Unit I/O memory (one of CIO, WR,
AO Terminal to CPU Unit
Expanded DI Terminal from
CPU Unit
Expanded DO Terminal
from CPU Unit
Expanded AI Terminal from
CPU Unit
Expanded AO Terminal
from CPU Unit
Receive All Blocks
Send All Blocks
Block Name
Block Name
Block Name
Sends 16 analog values to the send-to-computer area. When CX-Process Monitor is used,
Sends 2 analog values to nodes on the Controller Link Data Link.
Outputs max. 128 points from any leading address in CPU Unit I/O memory (one of CIO,
Outputs max. 8 words from any leading address in CPU Unit I/O memory (one of CIO, WR,
Sends 128 contacts to the send-to-computer area. When CX-Process Monitor is used, the
contact signals to be monitored are connected to this function block.
the analog signals to be monitored are connected to this function block.
Sends a specified 1 block to the send-to-computer area. When CX-Process Monitor is used,
the 1 block to be monitored are connected to this function block.
Sends a specified 4 block to the send-to-computer area. When CX-Process Monitor is used,
the 4 block to be monitored are connected to this function block.
Sends 32 contacts to nodes on the Controller Link Data Link.
Receives 32 contacts sent from the computer. (Can also be downloaded to the send-to-all
nodes area.)
Receives 2 analog values sent from the computer. (Can also be downloaded to the send-to-
all nodes area.)
HR, DM and EM area types). (read)
WR, HR, DM and EM area types). (read and write)
HR, DM and EM area types). (read)
HR, DM and EM area types). (read and write)
Inputs any contact data in CPU Unit I/O Memory, and writes max. 64 points on another func-
tion block.
Inputs the contact data of another function block, and writes max. 64 points on any I/O Mem-
ory in the CPU Unit.
Inputs any analog data in CPU Unit I/O Memory, and writes max. 64 words on another func-
tion block.
Inputs the analog data of another function block, and writes max. 64 words on any CPU Unit
I/O Memory.
Reads ITEM data specified for Send/ Receive All Blocks for up to 32 Control Blocks, 249 Op-
eration Blocks, and 32 External Controller Blocks starting from a specified address in the I/
O memory of the CPU Unit.
Writes ITEM data specified for Send/ Receive All Blocks for up to 32 Control Blocks, 249 Op-
eration Blocks, and 32 External Controller Blocks starting to a specified address in the I/O
memory of the CPU Unit.
Function
Function
Function
Node Terminal Blocks