T30UXDC BANNER ENGINEERING, T30UXDC Datasheet - Page 3

no-image

T30UXDC

Manufacturer Part Number
T30UXDC
Description
T30UX Series W/ Discrete Output
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of T30UXDC

Range
300 Mm To 3 M
Input
10 To 30V Dc
Output
NPN PNP NO NC Selectable
Body Style
Round
Range, Measurement
300 mm to 3 m
Response Time
135 ms
Voltage, Supply
10-30 VDC
Accessories Available
Cordsets and Brackets
Lead Free Status / Rohs Status
RoHS Compliant part
Two TEACH methods may be used to configure the sensor:
• Teach individual minimum and maximum limits, or
• Use Auto-Window feature to center a sensing window around the taught position.
The sensor may be configured either via its push button, or via a remote switch. Remote configuration also may be used to disable the push
button, preventing unauthorized personnel from adjusting the configuration settings. To access this feature, connect the white wire of the
sensor to 0V dc, with a remote configuration switch between the sensor and the voltage.
Configuration is accomplished by following the sequence of input pulses. The duration of each pulse (corresponding to a push button “click”),
and the period between multiple pulses, are defined as “T”:
Remote line configuration requires a > 1 second pause between pulse sequences.
Sensors can be set up for either NPN (sinking) or PNP (sourcing). In addition, the user can select between Normally Open (NO) and Normally
Closed (NC) operation. Normally Open is defined as the output energizing when the target is present. Normally Closed is defined as the output
energizing when the target is absent (see figure 2).
* The sensor will revert to previously saved configuration and return to RUN mode if TEACH is inactive for 120 seconds after the initial 2 second hold on push
button
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
...
• P ush and hold
• “ Click” the MODE push button
• P ush and hold
MODE push button
for > 2 seconds
to cycle to correct selection:
NPN - Normally Open
NPN - Normally Closed
PNP - Normally Open
PNP - Normally Closed
MODE push button
for > 2 seconds
...
Procedure
0.04 sec. < “click” < 0.8 sec
D
Push Button
...
...
Power LED: OFF
Mode LED: Flashing Amber
Power LED: OFF
Mode LED: Flashes to indicate
Power LED: ON Green
Mode LED: ON Amber for
...
...
U-GAGE
Mode Setup – Output Configuration
0.04 seconds < T < 0.8 seconds
.
Result
shows previously
selected mode
currently selected
mode
(120 second time
out*)
selected mode
Sensor Configuration
or
D
D
®
T30UX Series with Discrete Output
• D ouble-pulse the
• S ingle-pulse for NPN -
• D ouble-pulse for NPN -
• T riple Pulse for PNP -
• F our-pulse for PNP -
• N o action required; sensor
remote line
Normally Open
Normally Closed
Normally Open
Normally Closed
will return to Run Mode
T
T
T
Procedure
or
or
T
T T T
T
T
0.04 sec. < T < 0.8 sec
T
T
Remote Line
T
T
T
T
Power LED: OFF
Mode LED: Flashing Amber shows
Power LED: ON Green
Mode LED: ON to indicate
T
None
T
T
T
T
T
.
T
previously selected
mode
currently selected
mode
(Sensor returns to
RUN mode)
Result
T
T
P/N 138381 rev. B
T
T
T
T
3