Specifications of C396A2A005SELXB

Overload Adjustment Current Min
1A
Overload Adjustment Current Max
5A
Frame Size
Standard
Contact Configuration
1NO / 1NC
34-144
34
Table 34-181. Undervoltage Release — Technical Data and
Specifications
Cross-sections
Main Contacts
Power Consumption
Table 34-182. Current Limiter
Figure 34-103. XTPB, XTPR 1- and 2-Pole Circuits with DC and
AC Current
Figure 34-104. Protection of PVC Insulated Cables Against Thermal
Overload at Short Circuit
The table indicates which minimum cable cross-sections are
protected by XTPR motor protective circuit breakers up to
their rated conditional short circuit current I q .
Description
Solid or flexible conductor with ferrule (mm
Solid or stranded (AWG)
Rated operational voltage, U e (V AC)
Rated operational voltage, U e (V DC)
Pick-up voltage, x U s
Drop-out voltage, x U s
Pick-up AC (VA)
Sealing AC (VA)
Description
Rated Impulse withstand Voltage (U imp ), V AC
Overvoltage Category/ Pollution Degree
Rated operational voltage, U e (V AC)
Rated interrupted current = Rated operational current
(l u = l e ) in amperes
IEC Contactors & Starters
XT IEC Power Control
Manual Motor Protectors
Min. Cross-Section Protected
380-415V, 50 Hz, Cu mm
4
2.5
I > I > I >
1
2 4 6
1.5
3 5
1
2
0.75
2
)
I > I > I >
1 3 5
2 4 6
Device
Type
XTPRP16BC1
XTPR6P3BC1
XTPR010BC1
XTPR016BC1
XTPR020BC1
XTPR025BC1
XTPR016DC1
XTPR025DC1
XTPR032DC1
XTPR040DC1
XTPR050DC1
XTPR058DC1
XTPR063DC1
For more information visit: www.eaton.com
XTPAXUVR…
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (18 – 14)
2 x (18 – 14)
42 – 480
24 – 250
0.85 – 1.1
0.7 – 0.35
5
3
XTPAXCL
6000
III/3
690
63
Table 34-183. Shunt Release — Technical Data and Specifications
Cross-sections
Main Contacts
Power Consumption
Figure 34-105. Fuseless Installation with XTPR, Back-Up
Protection Diagrams
Description
Solid or flexible conductor with ferrule (mm
Solid or stranded (AWG)
Rated operational voltage, U e (V AC)
Rated operational voltage, U e (V DC)
AC Operating Range, x U s
DC Operating Range, x U s (intermittent operation 5s)
Pick-up AC (VA)
Sealing AC (VA)
Pick-up DC (VA)
Sealing DC (VA)
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
Back-up
protection
range
with XTPAXCL
Rated
short-circuit
breaking
capacity
range
XTPR…B
XTPR…D
415V AC
415V AC
XTPR…B
XTPR…D
100
100
50
30
20
16
10
50
30
20
16
10
6
6
XTPR...B
Inherently
short-circuit-proof
0.16...
16...
2
)
25
XTPR...D + XTPAXCL
XTPR…D
Rated
Current
n [A]
32
40
1016 20 25
XTPAXSR __
1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
1 x (18 – 14)
2 x (18 – 14)
42 – 480
24 – 250
0.7 – 1.1
0.7 – 1.1
5
3
3
3
50
CA08102001E
Rated
Current
March 2009
n [A]
Rated
Current
63
n [A]

Related parts for C396A2A005SELXB