C500CN812N Omron, C500CN812N Datasheet - Page 80

no-image

C500CN812N

Manufacturer Part Number
C500CN812N
Description
I/O CONNECTION CABLE
Manufacturer
Omron
Datasheet

Specifications of C500CN812N

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Note 1. This output is not provided on PS223-E.
Supply Voltage
Operating Voltage Range
Power Consumption
Output Capacity
24 VDC Output (see note 1)
Insulation Resistance
Dielectric Strength (see note 2)
Noise Immunity
Vibration Resistance
Shock resistance
Ambient Temperature
Ambient humidity
Atmosphere
Grounding
Degree of Protection
Weight
Power Supply Model
2. When performing the dielectric strength test or the insulation resistance test be sure to disconnect the
LG terminals from the GR (ground) terminals to protect the internal parts from damage.
C1000H
C2000H Simplex
C2000H Duplex
100 to 120/200 to 240 VAC (selectable)
50/60 Hz
85 to 132/170 to 264 VAC
150 VA max.
PS221-E: 7 A 5 VDC
PS223-E: 12 A 5 VDC
PS222-E: 7 A 5 VDC
0.8 A, 24 VDC 10%
5 MW min. (at 500 VDC) between AC terminals
1,500 VAC 50/60 Hz for 1 minute
(between AC and GR terminals) leakage
current 10 m A max.
1,000 Vp-p, pulse width: 1 ms, rise time: 1 ns
Mechanical durability: 10 to 25 Hz, 2 mm double amplitude, in X, Y, and Z
directions, for 2 hours each
Electrical durability: 16.7 Hz, 1 mm double amplitude, in X, Y, and Z directions, for
10 minutes each
98 m/s
Operating: 0°C to 55°C Storage: −20°C to 65°C
35% to 85% (without condensation)
Must be free from corrosive gasses
Less than 100 W
Mounted in a panel
8 kg max.
9 kg max.
10 kg max.
3G2A5-PS221-E/PS222-E/PS223-E
2
each in X, Y, and Z direction, 3 times
Specifications
Appendix B
24 VDC
20.4 to 28.8 VDC
55 W max.
PS211-E: 7 A 5 VDC
PS213-E: 9 A 5 VDC
PS212-E: 7 A 5 VDC
Not provided
500 VAC 50/60 Hz for 1 minute
(between DC and GR terminals) leakage
current 1 mA max.
3G2A5-PS211-E/PS212-E,
C500-PS213-E
67

Related parts for C500CN812N