C500IF001 Omron, C500IF001 Datasheet - Page 116

no-image

C500IF001

Manufacturer Part Number
C500IF001
Description
GPC COMMUNICATIONS ADAPTER
Manufacturer
Omron
Datasheet

Specifications of C500IF001

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Timer and Counter Instructions
Address
0000
0001
0002
0003
1813 (normally ON)
0002 (start input)
Instruction
LD
MOV(21)
MOV(21)
MOV(21)
The values must be four-digit BCD in the range 0000 through 9999. Failure
to enter BCD values will not activate the ERR flag. Always set a lower limit
which is less than the corresponding upper limit. MOV(21) is useful in setting
limits. The following ladder diagram shows the use of MOV(21) for setting
limits.
#
DM
#
DM
#
DM
Operands
1813
0200
1500
0600
00
01
02
0004
Address
0005
0006
Instruction
MOV(21)
LD
RDM(60)
Corresponding
result word is 05
RDM(60) 46
MOV(21)
MOV(21)
MOV(21)
MOV(21)
DM 00
DM 01
DM 02
DM 03
#0200
#1500
#0600
#2000
05
#
DM
Operands
Transfers
preset value
to DM 00 to
03.
Counts
inputs on
IR 1805.
2000
0002
03
46
05
Section 5-11
105

Related parts for C500IF001