RSC-HD0M60 CARLO GAVAZZI, RSC-HD0M60 Datasheet - Page 6

Motor Controller

RSC-HD0M60

Manufacturer Part Number
RSC-HD0M60
Description
Motor Controller
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of RSC-HD0M60

Current Limit Max
180mA
Supply Voltage Max
32VDC
Controller Features
Soft Start, Linear Ramp, Multivoltage
Supply Voltage Min
10VDC
Approval Bodies
CE
Current Limit Min
30mA
Supply Voltage Range
10VDC To 32VDC
For Use With
-000 Mm
RSC 4-HD.M60/RSO22..., RSO4...., RSO60...
This circuit limits the power
dissipation of the SSR and
consequently eliminates the
need for a large heatsink, i.e.
the power dissipation is limi-
ted to the starting and stop-
ping periods. This is achieved
by switching a contactor
with the output signal from
the control module RSC. In
this case C2 is carrying - not
switching - the current and
can therefore be rated on
the basis of the thermal cur-
6
Applications (cont.)
400 VACrms and 480 VACrms motors
600 VACrms motors
Shunting the output module
Selection Guide
Output module
Max. motor size
Output module
Max. motor size
U/T
L
1
3 HP/2.2 kW
1
RSO 4.10
V/T
L
M
2
2
W/T
L
rent data of the contacts,
which will result in a smaller
contactor.
Note: However, if C2 fails,
the temperature on the output
module RSO heatsink may
rise to an unacceptable level.
It is therefore advisable to
protect the RSO by means
of an optional temperature
limiting switch T1, which can
be inserted in the housing of
the output module.
3
3
Power
supply
Pilot
voltage
5 HP/4 kW
RSO 4.25
The MS1 .. Power Supply connected to a motor controller
(RSC) for soft starting/soft stopping of an induction motor.
15 HP/11 kW
RSO 6050
RSO 4.50
Specifications are subject to change without notice (30.06.1999)
15 HP
1/L
2/T
20 HP/15 kW
RSO 6090
RSO 4.90
3/L
4/T
30 HP
6/T
5/L
Start/stop of RSC:
Start: Activate S1 until the
Stop: Activate S2
motor is fully on
Pilot voltage
30 HP/22 kW
RSO 60110
RSO 4.110
40 HP

Related parts for RSC-HD0M60