--------------------------pH / CONDUCTIVITY
--------------------------pH / 3-RANGE CONDUCTIVITY
--------------------------pH
--------------------------4-RANGE CONDUCTIVITY
--------------------------DISSOLVED OXYGEN
DP-03 --------------3-range conductivity, 0-50, 0-500, 0-5000 ppm, 0-75 0-750, 0-7500 µmhos . . . . . . . . . . . . . . . .$275.00
DP-04 --------------Conductivity, 0 to 1200 PPM, 0 to 1800 µmhos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185.00
DP-04D ------------Resistivity: infinity to 20,000ohms/in⁄, 400ohms/in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$295.00
PHA-10 -----------Buffer solution, pH 10.01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$10.00
CDS-0 ------------Cleaning solution for conductivity probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.95
CDS-1 ------------Salt analyzer calibration solution 1% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.95
CDS-10 -----------Salt analyzer calibration solution 10% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.95
CDS-45 ----------Conductivity solution 45µmhos/cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-450 ---------Conductivity solution 450µmhos/cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-1500 -------Conductivity solution 1500µmhos/cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
CDS-4500 -------Conductivity solution 4500µmhos/cm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.00
DSPH-1BPPM
DSPH-1BUS
DSPH-3BPPM
DSPH-3BUS
PH-2
TDS-4
D0-6
DP SERIES
HAND HELD ANALOG INSTRUMENTS FOR CONDUCTIVITY AND RESISTIVITY
The DP series meters are simple to operate, battery powered portable meters which indicate either
conductivity or resistivity on a stable, easy to read analog display, designed and calibrated specifically for
monitoring water quality. They feature integral sample cup sensors, water and chemically resistant ABS
cases, and rubber booted switches. The instrument handle for protection make the instruments ideal for
users requiring portability without sacrificing reliability. Each Pocket Pal
battery, calibration screwdriver protective carrying case, calibration standards and instructions for use.
CONDUCTIVITY
The DP-03 and DP-04 display conductivity in both Micromhos and Parts Per Million and feature automatic
temperature compensation. The DP-04 is ideal for the performance of Reverse Osmosis and other
drinking water filtration systems with a single range of 0-1200PPM. The DP-03 displays conductivity
across three switchable ranges of 0-50, 0-500 and 0-5000 providing improved accuracy and readability.
RESISTIVITY
The DP-04D is designed for water quality measurements in the Ultra Pure range and displays
Resistivity across two switchable ranges of infinity to 20,000 ohm/in⁄and infinity to 400 ohm/in⁄.
ACCESSORIES
POCKET PAL
HAND HELD POCKET PAL INSTRUMENTS FOR pH, CONDUCTIVITY, ORP, DISSOLVED OXYGEN,
SALT CONCENTRATION, AND TEMPERATURE
Pocket Pal instruments are ideal for laboratory and field analysis applications. Unique packaging permits
one-hand operation, freeing the other for sample collection and manipulation. Electrodes are designed for
ease of field replacement and can be recalibrated in minutes with easy access two point calibration. ABS
plastic housing and probes which fold-away into the instrument handle for protection make the instruments
ideal for users requiring portability without sacrificing reliability. Each Pocket Pal comes complete with 9-volt
battery, calibration screwdriver protective carrying case, calibration standards and instructions for use.
0-14.00pH, resolution 0.01, accuracy ±0.02pH, 0-70°C. Conductivity resolution 10, accuracy ±2%fs, 0-50°C
pH / conductivity range 0-20,000 ppm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$360.00
pH / conductivity range 0-20,000 µS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360.00
0-14.00pH, resolution 0.01, accuracy ±0.02pH, 0-70°C. Conductivity resolutions 1, 10, 100
accuracy ±0.2%fs, 0-50°C
pH/3-range conductivity 2,000, 20,000, 200,000 ppm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$410.00
pH/3-range conductivity 2,000, 20,000, 200,000 µs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .410.00
0-14.00pH, resolution 0.01, accuracy ±0.04pH, 0-100°C
Ideal for general purpose pH measurements, with manual temperature compensation
and replaceable probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$199.00
Conductivity resolutions .1, 1, 10, 100, Accuracy ±1%FS or ±1.5%
FS for 0-200,000 ±.01% 0-50°C ±.03% 50-70°C
4-range conductivity 0-200, 2,000, 20,000 and 200,000µs. Uses 100 ohm RTD for
0-19.99 ppm ±.1ppm, 0-40°C, Temperature 0-80°C ±.2°C
Dissolved oxygen meter with integral temperature sensor and switch selectable display . . . . .$485.00
automatic temperature compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$340.00
®