BSCF NEWPORT ELECTRONICS, BSCF Datasheet - Page 9

no-image

BSCF

Manufacturer Part Number
BSCF
Description
BOARD-TRMS VOLT./CURR. - NEWPORT
Manufacturer
NEWPORT ELECTRONICS
Datasheet

Specifications of BSCF

Rohs Compliant
NA
*
*
1
2
Analog Output (Option 5) is not available with -AL units.
Internal excitation is not available with -DC power option, -C4EI or -C24 options.
--------------------------Monitor only
--------------------------Controller with Two Control Outputs
--------------------------ALARM
--------------------------NETWORK OPTIONS
--------------------------POWER SUPPLY OPTIONS
--------------------------FACTORY SETUP
iS32** --------------Controller (two control outputs) 1/32 DIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240.00
-AL
-C24
EIS-2
*
-DC
-FS
iS3200 -------------Monitor only (no control outputs) 1/32 DIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195.00
22
23
24
33
42
43
44
52
53
54
Two solid state relays (SSR's): 0.5A @120/240 Vac
0.5A SSR and Form "C" SPDT 3A relay 120/240 Vac
0.5A SSR and pulsed 10 Vdc@20mA (for external SSR)
Two form "C" SPDT 3A relays 120/240 Vac
Pulsed 10 Vdc @ 20 mA (for external SSR) and SSR
Pulsed 10 Vdc @ 20 mA (for external SSR) and relay: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac
Two pulsed 10 Vdc @ 20 mA (for external SSR's)
Analog output selectable as either control or retransmission of process value;
0-20mA@500 ohm max or 0-10 Vdc. Second output SSR 0.5A @ 120/240 Vac
Analog output selectable as either control or retransmission of process value;
0-20mA@500 ohm max or 0-10 Vdc, and form "C" SPDT relay 3A @ 120/240 Vac
Analog output selectable as either control or retransmission of process value;
0-20mA@500 ohm max or 0-10 Vdc, and pulsed 10 Vdc@20mA max (external SSR)
iSERIES iS32XX
1/32 DIN STRAIN/PROCESS METERS AND CONTROLLERS CAN CHANGE COLOR AT ANY SET POINT.
1/32 DIN size (24mm x 48mm) meter or controller can be programmed to change color at any set point
or alarm point, and feature 9-segment LED characters. The i32 handles more thermocouple, RTD,
process voltage and current inputs than any other 1/32 DIN controller; with built-in excitation for
transmitters or other devices, 24 Vdc @ 25mA. 2 SPDT (Single Pole Double Throw) Form C relays.
Both RS-232 and RS-422/485 serial communications in one instrument (C24 option). Both ASCII
protocol and Modbus protocol are selectable from the menu.
**Please select desired output configuration from list below.
Limit Alarm Version (Simplified Menu; No PID Control) *
Isolated RS-232 and RS-485 300 to 19.2 k baud *
Embedded Internet Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$195.00
Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry required) . . . . . . . . . . . . . . . . . . . . .NC
12-36 Vdc, 24 Vac *
Factory Setup and configuration (requires -C24 Serial Communication option) . . . . . . . . . . . . . . . . .NC
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$25.00
9
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$60.00
3
*
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NC

Related parts for BSCF