EPAX0500 Red Lion Controls, EPAX0500 Datasheet - Page 3

Multifunction Meter

EPAX0500

Manufacturer Part Number
EPAX0500
Description
Multifunction Meter
Manufacturer
Red Lion Controls
Type
Multi-Functionr
Datasheet

Specifications of EPAX0500

No. Of Digits / Alpha
5
Panel Cutout Height
6.23"
Panel Cutout Width
23.79mm
Signal Input Type
Current, Process, Strain Gage, Thermocouple, Voltage
Meter Signal Input
Current, Process, Thermocouple, Voltage
Application
For industrial
Connection Type
Cage-Clamp
Cut Out, Panel
23.79×6.23 "
Digit Height
0.35
Dimensions
24.77"L×4.65"W×7.22"H
Display Digit Height
4 "
Display Type
LED
Function
Ammeter/Process/Strain Gage/Temperature/Voltage
Humidity
0 to 85%
Material, Casing
Aluminum
Number Of Digits
8
Primary Type
Electronic
Range, Measurement
-19999 to 99999
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Voltage, Input
85 to 250 VAC
Voltage, Supply
85 to 250 VAC
Sealing
NEMA 4/IP65
Character Size
4"
Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Red Lion MPAXD000, MPAXH000, MPAXP000 And MPAXT000 MPAX Modules
the MPAX and any option cards be assembled first. This will
allow you the opportunity to insure all the boards are fitted
properly into their connectors.
Installing the Option Cards
installed into the MPAX before it is installed into the EPAX
Display. Refer to the literature enclosed with the option cards for
installation instruction.
Installing the MPAX
EPAX by removing the two screws and pulling off the metal
holding bracket. Install the MPAX into plastic case by
aligning the front connector of the MPAX with the hole in
the front of the plastic case. The module must be oriented
as shown with terminal #1 toward the top of the EPAX
case. Next, insert the MPAX case into the EPAX by lightly
pushing the connector of the MPAX into the connector of
the EPAX PC board. Place holding bracket over the plastic
case and install the two screws.
Installing the Labels
label. These labels must be applied to the rear of the EPAX in the
positions shown in the drawing.
Removing The MPAX Module
power and load circuits. Then insert a flat screwdriver blade (
or
and the module’s plastic cover as illustrated in Figure 2.
Twist the screwdriver in the direction shown to
disengage the internal connectors while firmly
squeezing and pulling back on the rear
finger tabs (top and bottom).
Carefully slide the module out
of the EPAX case, keeping
it properly aligned
with the case
opening.
1.0 ASSEMBLING THE DISPLAY
1
Prior to installing the EPAX Display, it is recommended that
If your application requires option cards, they should be
Remove the MPAX case (plastic) from the rear of the
Each option card and the MPAX are shipped with a connection
To remove the MPAX Module from the EPAX Display, first remove all
/
4
") into the narrow slot between the EPAX rear cover plate
CAUTION: The MPAX main circuit board and the option cards
contain static sensitive components. Before handling the module
or the cards, discharge static charges from your body by
touching a grounded bare metal object. Handle the module by
the rear plastic cover only, and the option cards by the board
edges. Dirt, oil or other contaminants that contact the circuit
boards or components can adversely affect circuit operation.
3
/
16
"
Figure 2, Removing an MPAX Module
Figure 1, Installing an MPAX Module and Option Cards
3
WARNING: Exposed line voltage exists on the MPAX main circuit
NOTE: All module and option card labels must be installed as
board and the option cards. DO NOT apply power to the
module OR load circuits until the module is properly installed
in the EPAX case.
shown for safety purposes.

Related parts for EPAX0500