Specifications of 35074

Meter Function
AC Ammeter
Meter Range
0A To 25A
Meter Size/dimensions
3.5 In.
Scale Length
79.9mm
Meter Shape
Rectangular
Display Accuracy ±
2%
Current Meter Range
0-25 A
Accuracy
+/-2 %
Barrel Size
2.79"
Connection Type
Stud
Diameter, Body
2.73 in.
Diameter, Mounting Hole
0.128 in.
Dimensions
3.25"L×3.25"H
Display Type
Analog
Function
Ammeter
Impedance
0.008 Ohms @ 60 Hz
Material, Casing
Plastic
Measuring Range
0 to 25 ACA
Primary Type
Electromechanical
Range, Measurement
0 to 25 AAC
Repeatability
2%
Size
3-1⁄2 in.
Size, Thread
1⁄4-28
Special Features
Extended Operatiing Temp
Standards
UL Recognized
Temperature, Operating
-20 to +65 °C
Tracking
±3%
Response Time
1.5 Seconds Maximum
Equipment Type
AC Current Meter
Range
0 - 25
Meter Movement
Iron-Vane
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
35074-8001
Manufacturer:
MOLEX
Quantity:
44 663
Part Number:
35074-8001
Manufacturer:
TE
Quantity:
35 000
Part Number:
35074-9002
Manufacturer:
MOLEX
Quantity:
15 600
Part Number:
35074/BCAJC
Manufacturer:
TI
Quantity:
2 232
Part Number:
35074/BCBJC
Quantity:
2 546
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
• Only 3.12” (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional
• Din Rail Adapter available
Mounting Requirements
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
point setting and display scaling
(page C1)
Dimensions
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ACCURACY @25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
4.04”
3.59”
3.75
1.88
7-segment, red LED
0.56" (14.2mm)
3 or 4 position user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
±0.02% of reading ± 1 count
750 ± 2 count
±0.1% of reading ± 1 count
750 ± 2 count
±0.05% of reading ±1 count
2A ± 5 counts
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz-1KHz)
±0.5% of reading ± 35 counts (45Hz-1KHz)
±1% of reading ± 5 counts (45Hz-1KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
(±0.1% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
50dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min.
Dual slope integration
3 samples per second, nominal
3.75" x 1.88" x .51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1g)
.51
2.94
5A ± 5 counts
92 mm
1.75
more >>
2.26
A
7