35074 Simpson, 35074 Datasheet - Page 26

Current Meter

35074

Manufacturer Part Number
35074
Description
Current Meter
Manufacturer
Simpson
Type
Ammeterr
Datasheets

Specifications of 35074

Meter Function
AC Ammeter
Meter Range
0A To 25A
Meter Size/dimensions
3.5 In.
Scale Length
79.9mm
Meter Shape
Rectangular
Display Accuracy ±
2%
Current Meter Range
0-25 A
Accuracy
+/-2 %
Barrel Size
2.79"
Connection Type
Stud
Diameter, Body
2.73 in.
Diameter, Mounting Hole
0.128 in.
Dimensions
3.25"L×3.25"H
Display Type
Analog
Function
Ammeter
Impedance
0.008 Ohms @ 60 Hz
Material, Casing
Plastic
Measuring Range
0 to 25 ACA
Primary Type
Electromechanical
Range, Measurement
0 to 25 AAC
Repeatability
2%
Size
3-1⁄2 in.
Size, Thread
1⁄4-28
Special Features
Extended Operatiing Temp
Standards
UL Recognized
Temperature, Operating
-20 to +65 °C
Tracking
±3%
Response Time
1.5 Seconds Maximum
Equipment Type
AC Current Meter
Range
0 - 25
Meter Movement
Iron-Vane
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
35074-8001
Manufacturer:
MOLEX
Quantity:
44 663
Part Number:
35074-8001
Manufacturer:
TE
Quantity:
35 000
Part Number:
35074-9002
Manufacturer:
MOLEX
Quantity:
15 600
Part Number:
35074/BCAJC
Manufacturer:
TI
Quantity:
2 232
Part Number:
35074/BCBJC
Quantity:
2 546
22
A
• Easily programmed from the front panel
• Remote Reset capability
• Input variety: Quadrature, Switch, TTL,
• Software functions include:
This counter offers a wide input frequency range from 1Hz to 35KHz,
and four display ranges of 99.99Hz, 999.9Hz, 9999Hz, and 35KHz.
The easiest to use counter in the S660 counter series, the S664
offers 12 DCV, 100mA sensor excitation and requires no program-
ming to use.
After the counter is mounted and wired, selecting the appropriate fre-
quency range is the only setup required. One of four frequency
ranges may be selected to measure from 1Hz to 35KHz.
Mounting Requirements
The S660 series 1/8 DIN counters require a panel cutout of 1.77"
(45mm) high by 3.62" (92mm) wide. To install the counter into a
panel cutout, remove the clips from the side of the meter. Slide the
meter through your panel cutout, then slide the mounting clips back
on the meter. Press evenly to ensure a proper fit.
CMOS, NAMUR, PNP, NPN
Password
Set Point Programming
Panel Cutout Dimensions on page A23
Display Scaling
Decimal Point Selection
Specifications
DISPLAY
Type
Height
Decimal Point
Count Direction
Display Range
Output Indicators
POWER REQUIREMENTS
AC Voltages
Power Consumption
INPUT RATINGS
Current Sinking
Current Sourcing
Minimum Pulse Width
Low Pass Filter
Low Bias
High Bias
Count Rate
Maximum Voltage Input
A, B, and User
ENVIRONMENTAL
Operating Temp.
Storage Temp.
Relative Humidity
Ambient Temperature
Temp. Coefficient (per °C)
Warmup Time
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
Ordering Information
Basic Unit
S664
120 ACV
240 ACV
Power Supply
Standard
Quadrature
1
2
Input
4-digit, 7-segment, red LED
0.56" (14.2mm)
Position according to scale selection
"+" indication implied, "-" indication displayed
-999 to +9999
1 and 2
120, 240VAC, ±10%
3VA
10K , 5% Resistor pull-up to (9.0 - 16DCV) ±10%
5.1K , 5% Resistor pull-down to common
~2µs
<200Hz
VLT = 1.6V ±10% VUT = 3.6V ±10%
VLT = 5.0V ±10% VUT = 7.0V ±10%
35KHz (Pulse Max) 8.75KHz (Quadrature X4
Max)
30DCV (Max)
0°C to +40°C
-10°C to +60°C
0-80% non-condensing for temperatures less
than 32°C, decreasing linearly to 50% at 40°C
25°C
±100ppm/ °C
15 minutes
3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm)
3.24" (82.3mm)
3.62" x 1.77" (92mm x 45mm)
PBT-ABS
9oz (255.1g)
1
2
Output
None
100mA Max Current
0
Excitation
12DCV
None
None
Other
0
1
0