0779185-401 VEEDER ROOT, 0779185-401 Datasheet - Page 117

Electromechanical Totalizing Counter

0779185-401

Manufacturer Part Number
0779185-401
Description
Electromechanical Totalizing Counter
Manufacturer
VEEDER ROOT
Datasheet

Specifications of 0779185-401

No. Of Digits / Alpha
5
Digit Height
4mm
Power Consumption
5VA
Operating Temperature Range
0°C To +50°C
Mounting Type
Rear
Counter Supply Voltage
115VAC
Lead Free Status / RoHS Status
na
OUTPUT OPERATING MODES
ON-Delay Operation
ON-Delay Operation with Time Totalization
WIRING
MOUNTING
The SX210 timer uses two removable mounting clips with adjustable screws to mount the enclosure in a panel as shown below. To mount the unit, slide the
gasket onto the case until it is against the back of the bezel and place the unit in the panel cutout from the front of the panel.
ORDERING INFORMATION
The contacts operate as they do in the ON-Delay mode above.
When the timing cycle is completed and the programmed contacts
are energized, the SX210 timer begins time totalizing and continues
until the unit is reset.
PROGRAMMED
START INPUT
CONTACTS
(75.69)
2.98
INSTANTANEOUS CONTACT OPERATION
INSTANTANEOUS
1
15
14
CONTACTS
TIMING
6
OUTPUT TYPE
(75.69)
2.98
Sym.
10
10
8
9
7
PROGRAMMED
Relay Output
4
11
CONTACTS
TIME
Description
3
13
5
12
2
RESET
RESET
SX2
PANEL CUTOUT
SQUARE
2.72
(68
+0.7
-0.0
+0.028
-0.000
)
10
(5.84)
0.23
Interval Operation
Interval Operation with Time Totalization
Single-Pulse Operation
Pulse and Repeat Operation
PROGRAMMED
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
PROGRAMMED
PROGRAMMED
The contacts operate as they do in the Interval mode above. The
contacts are energized during the timing cycle and deenergize at the
end of the timing cycle. When the timing cycle is completed and the
programmed contacts are deenergized, the SX210 timer begins time
totalizing and continues until the unit is reset.
START INPUT
START INPUT
CONTACTS
START INPUT
CONTACTS
CONTACTS
A6
yy
yy
yy
yy
VOLTAGE & FREQUENCY
yyy
yyy
yyy yy
Sym.
yy
A6
B6
PANEL THICKNESS (STEEL)
0.125 – 0.313 (3.125 – 7.825)
INSTANTANEOUS CONTACT OPERATION
INSTANTANEOUS CONTACT OPERATION
INSTANTANEOUS CONTACT OPERATION
TIMING
120 VAC, 50/60 Hz
240 VAC, 50/60 Hz
TIMING
Description
TIMING
(127.0)
5.00
PULSE
PULSE
TIMING
PULSE
0.50 REQUIRED
FOR WIRING
RESET
RESET
RESET
5.23
T
O
T
A
Z
N
G
L
I
I
E
L
E
C
T
R
O
N
C
I
5
M
R
T
E
S
I

Related parts for 0779185-401