CS1W-CN313 Omron, CS1W-CN313 Datasheet - Page 69

no-image

CS1W-CN313

Manufacturer Part Number
CS1W-CN313
Description
"CABLE CS1 EXP I/O,30cm"
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Unit Specifications
AR area
TR area
LR area (note 1)
Timer/Counter
area (note 3)
DM area Read/
EM area
Data area
write
Read-
only
(note
4)
Error
history
area
(note
4)
PC
Setup
(note
4)
448
bits
8 bits
1,024
bits
512
bits
3,072
words
3,072
words
425
words
31
words
56
words
6,144
words
Size
Note
AR 00 to AR 27
---
LR 00 to LR 63
TIM/CNT 000 to TIM/CNT 511
(timer/counter numbers)
DM 0000 to
DM 3071
DM 3072 to
DM 6143
DM 6144 to
DM 6568
DM 6569 to
DM 6599
DM 6600 to
DM 6655
EM 0000 to
EM 6143
Words
1. IR and LR bits that are not used for their allocated functions can be used
2. A minimum of 2,528 bits are available as work bits. Other bits can be used
3. When accessing a PV, TIM/CNT numbers are used as word address; when
4. DM 6144 to DM 6655 cannot be written from the program.
as work bits.
as work bits when they are not used for their allocated functions, so the to-
tal number of available work bits depends on the configuration of the PC.
accessing Completion Flags, they are used as bit addresses.
AR 0000 to AR 2715
TR 0 to TR 7
LR 0000 to LR 6315
---
---
---
---
---
---
Bits
These bits serve specific functions such as flags
and control bits.
These bits are used to temporarily store ON/OFF
status at program branches.
Used for 1:1 data link through the RS-232 port or
through a Controller Link Unit.
The same numbers are used for both timers and
counters. When TIMH(15) is being used, timer
numbers 000 to 015 can be interrupt-refreshed
to ensure proper timing during long cycles.
DM area data can be accessed in word units
only. Word values are retained when the power
is turned off.
Available in CQM1H-CPU51/61 CPU Units only.
Cannot be written from the program (only from a
Programming Device).
DM 6400 to DM 6409 (10 words):
DM 6450 to DM 6499 (50 words):
DM 6550 to DM 6559 (10 words):
Used to store the time of occurrence and error
code of errors that occur.
Used to store various parameters that control PC
operation.
EM area data can be accessed in word units
only. Word values are retained when the power
is turned off.
Available in the CQM1H-CPU61 CPU Unit only.
Controller Link parameters
Routing tables
Serial Communications Board settings
Function
Section 2-1
47