88 970 119 Crouzet USA, 88 970 119 Datasheet - Page 4

M3 GSM MODEM

88 970 119

Manufacturer Part Number
88 970 119
Description
M3 GSM MODEM
Manufacturer
Crouzet USA
Datasheet

Specifications of 88 970 119

Ip/nema Rating
IP20, IP40
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CE, CSA, FCC, IC, PTCRB, R&TTE, UL
External Depth
54.5mm
External Length / Height
111mm
Mounting
RoHS Compliant
Mounting Type
DIN Rail
Rohs Compliant
Yes
For Use With
Remote Control Application
14/01/2010
Inputs used as digital inputs
Characteristics of relay outputs common to the entire range
Digital / PWM solid state output
Type
Accuracy at 55°C
Repeat accuracy at 55 °C
Isolation between analogue channel and power supply
Cable length
Protection against polarity inversions
Potentiometer control
Input voltage
Input current
Input impedance
Logic 1 voltage threshold
Making current at logic state 1
Logic 0 voltage threshold
Release current at logic state 0
Response time
Maximum counting frequency
Sensor type
Conforming to IEC/EN 61131-2
Input type
Isolation between power supply and inputs
Isolation between inputs
Protection against polarity inversions
Status indicator
Max. breaking voltage
Max. Output Common Current
Breaking current
Electrical durability for 500 000 operating cycles
Minimum switching capacity
Minimum load
Maximum rate
Mechanical life
Voltage for withstanding shocks
Response time
Built-in protections
Status indicator
PWM solid state output*
Breaking voltage
Nominal voltage
Nominal current
Max. breaking current
Voltage drop
Response time
Built-in protections
Min. load
Maximum incandescent load
Galvanic isolation
PWM frequency
PWM cyclic ratio
PWM accuracy at 120 Hz
PWM accuracy at 500 Hz
Status indicator
Description
± 6.2%
± 2%
None
10 m maximum, with shielded cable (sensor not isolated)
Yes
2.2 kΩ/0.5 W (recommended)
10 kΩ max.
12 V DC (-13% / +20%)
0,7 mA @ 10,44 VDC
0,9 mA @ 12,0 VDC
1,0 mA @ 14,4VDC
14 kΩ
≥ 7 V DC
≥0.5 mA
≤ 3 V DC
≤0.2 mA
1 →2 cycle times
In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr)
Contact or 3-wire PNP
Type 1
Resistive
None
None
Yes
On LCD screen for CD and XD
5 →30 V DC
24 →250 V AC
12A for O8,O9,OA
CB-CD-XD10-XB10-XR06-XR10: 8 A
XD26-XB26: 8 x 8 A relays, 2 x 5 A relays
XE10: 4 x 5 A relays
XR14: 4 x 8 A relays, 2 x 5 A relays
Usage category DC-12: 24 V, 1.5 A
Usage category DC-13: 24 V (L/R = 10 ms), 0.6 A
Usage category AC-12: 230 V, 1.5 A
Usage category AC-15: 230 V, 0.9 A
10 mA (at minimum voltage of 12 V)
12 V, 10 mA
Off load: 10 Hz
At operating current: 0.1 Hz
10,000,000 operations (cycles)
In accordance with IEC/EN 60947-1 and IEC/EN 60664-1: 4 kV
Make 10 ms
Release 5 ms
Against short-circuits: None
Against overvoltages and overloads: None
On LCD screen for CD and XD
CB12: O4
XD26: O4 →O7
* Only available with "FBD" programming language
10.4 →30 VDC
12-24 V DC
0.5 A
0,625 A
≤ 2 V for I = 0.5 A (at state 1)
Make ≤ 1 ms
Release ≤ 1 ms
Against overloads and short-circuits: Yes
Against overvoltages (*) : Yes
Against inversions of power supply: Yes
(*) In the absence of a volt-free contact between the output of the logic controller and the load
1 mA
0,2 A / 12 V DC
0,1 A / 24 V DC
No
14.11 Hz
56.45 Hz
112.90 Hz
225.80 Hz
451.59 Hz
1806.37 Hz
0 →100% (256 steps for CD, XD and 1024 for XA)
< 5% (20% →80%) load at 10 mA
< 10% (20% →80%) load at 10 mA
On LCD screen for XD
Code
www.crouzet.com

Related parts for 88 970 119