88 970 117 Crouzet USA, 88 970 117 Datasheet

M3 MODEM INTERFACE

88 970 117

Manufacturer Part Number
88 970 117
Description
M3 MODEM INTERFACE
Manufacturer
Crouzet USA
Datasheet

Specifications of 88 970 117

Ip/nema Rating
IP20, IP40
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CSA, UL
External Depth
70mm
External Length / Height
90mm
Mounting Type
DIN Rail
Supply Voltage
RoHS Compliant
Supply Voltage Max
24VDC
Rohs Compliant
Yes
For Use With
Remote Control Application
14/01/2010
88970119-GSM
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Characteristics of the communication Modem system
General characteristics
Supply
Certifications
Conformity with the low voltage directive
Conformity with the EMC directive
Earthing
Protection rating
Overvoltage category
Pollution
Maximum utilisation altitude
Mechanical resistance
Resistance to electrostatic discharge
Resistance to HF interference
Conducted and radiated emissions
Operating temperature
Storage temperature
Relative humidity
Mounting
Screw terminals connection capacity
Certifications
Nominal voltage (V)
Operating limits
Ripple
Nominal current under 12 V DC
- STN modem for wired transmission networks
- GSM modem for wireless communication
For remote control of your application
Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
Millenium 3 program can be downloaded, modified and sent
Input and output states, as well as all program values, can be polled and controlled remotely
2 types of pre-configured ready-to-use modem:
UL, CSA
GL: except for 88 970 32x (pending)
In accordance with 73/23/EEC:
EN (IEC) 61131-2 (Open equipment)
In accordance with 89/336/EEC:
EN (IEC) 61131-2 (Zone B)
EN (IEC) 61000-6-2,
EN (IEC) 61000-6-3 (*)
EN (IEC) 61000-6-4
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B: using in metallic
cabinet)
None
In accordance with IEC/EN 60529:
IP40 on front panel
IP20 on terminal block
3 in accordance with IEC/EN 60664-1
Degree: 2 in accordance with IEC/EN 61131-2
Operation: 2000 m
Transport: 3,048 m
Immunity to vibrations IEC/EN 60068-2-6, Fc test
Immunity to shock IEC/EN 60068-2-27, Fa test
Immunity to ESD IEC/EN 61000-4-2, level 3
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3,
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Class B (*) in accordance with EN 55022/11 group 1
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in metallic cabinet)
-20 →+55°C (+40°C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
-40 →+70°C in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
95% max. (no condensation or dripping water) in accordance with IEC/EN 60068-2-30
On symmetrical DIN profile, 35 x 7.5 mm and 35 mm x 15 or panel (2 x 4 mm Ø)
Flexible wire with ferrule =
1 conductor: 0.25 to 2.5 mm² (AWG 24...AWG 14)
2 conductors 0.25 to 0.75 mm² (AWG 24...AWG 18)
Semi-rigid wire =
1 conductor: 0.2 to 2.5 mm² (AWG 25...AWG 14)
Rigid wire =
1 conductor: 0.2 to 2.5 mm² (AWG 25...AWG 14)
2 conductors 0.2 to 1.5 mm² (AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
See page 22, except:
UL, CSA
12 →24 V DC
-13% / + 20%
or 10 →28,8 V DC
5% max.
30 mA
www.crouzet.com

Related parts for 88 970 117

88 970 117 Summary of contents

Page 1

For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email with M3 ALARM software. Millenium 3 program can be downloaded, modified and sent Input and output states, as well ...

Page 2

Nominal current under Peak current on energisation Max. absorbed power Immunity from micro power cuts Protection against polarity inversions Fuse protection Characteristics of the "COM-M3" link with the controller Type of connector Type of link Compatibility Isolation ...

Page 3

Response time with function blocks programming Maximum counting frequency Sensor type Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator Characteristics of relay outputs common to the entire range Max. breaking voltage ...

Page 4

Accuracy at 55°C Repeat accuracy at 55 °C Isolation between analogue channel and power supply Cable length Protection against polarity inversions Potentiometer control Inputs used as digital inputs Input voltage Input current Input impedance Logic 1 voltage threshold Making current ...

Page 5

PA 1,80 m serial link cable: DB9/DB9 M3 ALARM Alarm management software (CD-ROM 14/01/2010 www.crouzet.com 88970123 88970116 ...

Related keywords