E5GN-Q03P-FLK AC100-240 Omron, E5GN-Q03P-FLK AC100-240 Datasheet - Page 10

no-image

E5GN-Q03P-FLK AC100-240

Manufacturer Part Number
E5GN-Q03P-FLK AC100-240
Description
TEMPERATURE CONTROLLER
Manufacturer
Omron
Series
E5GNr
Type
Temperature Controller, Digitalr
Datasheet

Specifications of E5GN-Q03P-FLK AC100-240

Rohs Compliant
YES
Input Type
RTD
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
100 ~ 240VAC
Size
48mm W x 24mm H (1/32 DIN)
Features
NEMA 4X, IP66
Communications
RS-485 (CompoWay/F)
Display Type
4 Digit (2)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5GN-Q03P-FLKAC100-240
E5GNQ03PFLKAC100240
Specification Setting after Turning ON Power
Initial Setting Level
This level is used for setting basic specifications of the Temperature
Controller. Using this level, set the input type for selecting the input to
be connected such as the thermocouple or platinum resistance ther-
mometer and set the range of set point and the alarm mode.
The move from the operation level to the initial setting level, press
key for three seconds or more.
The initial setting level is not displayed when “initial/communications
protection” is set to “2.” This initial setting level can be used when
“initial setting/communications protection” is set to “0” or “1.”
The “scaling upper limit,” “scaling lower limit,” and “decimal point”
parameters are displayed when an analog voltage input is selected
as the input type.
10
1 second min.
1 second min.
Operation level
Power ON
key
Initial setting
level
key
Digital Temperature Controllers
Advanced function
setting level
3 seconds
min.
Calibration level
Less than 1 second
key
key
Less than 1 second
Password input
set value "1201"
Password input
set value " 169"
25
Adjustment level
key
100
Communica-
tions setting
level
Control stops.
1 second min.
+
Control in progress
Control stopped
Level change
The time taken to move
to the protect level can
be adjusted by changing
the "Move to protect lev-
el time" setting.
key
Protect level
Display flashes
when key pressed.
+
E5GN
key
25
3 seconds
min.
+
100
key
To return to the operation level, press the
second.
c
c
in-t
in-h
in-l
sl-h
sl-l
cntl
s-hc
c-cp
ore?
alt1
amo?
Initial Setting Level
d-u
dp
st
cp
1300
-200
onof
stnd
or-r
100
on
20
20
0
0
0
c
2
0
Input type
Scaling upper limit
Scaling lower limit
Decimal point
Temperature unit
SP upper limit
Limit the set point.
SP lower limit
PID ON/OFF
Standard or
heating/cooling
ST
For input type of temperature,
standard, or PID
Control period (heating)
Set the pulse output cycle.
Control period (cooling)
Direct/reverse operation
Alarm 1 type
Move to advanced
function setting level
Displayed when initial setting/
communications protection is set to 0
C, F
key for longer than one

Related parts for E5GN-Q03P-FLK AC100-240