E5GN-Q03P-FLK AC100-240 Omron, E5GN-Q03P-FLK AC100-240 Datasheet - Page 12

no-image

E5GN-Q03P-FLK AC100-240

Manufacturer Part Number
E5GN-Q03P-FLK AC100-240
Description
TEMPERATURE CONTROLLER
Manufacturer
Omron
Series
E5GNr
Type
Temperature Controller, Digitalr
Datasheet

Specifications of E5GN-Q03P-FLK AC100-240

Rohs Compliant
YES
Input Type
RTD
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
100 ~ 240VAC
Size
48mm W x 24mm H (1/32 DIN)
Features
NEMA 4X, IP66
Communications
RS-485 (CompoWay/F)
Display Type
4 Digit (2)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5GN-Q03P-FLKAC100-240
E5GNQ03PFLKAC100240
12
c
c
alfa
ol-h
ol-l
p?ad
o-dp
a1lt
prlt
sero
init
mspu
sprt
rest
al1n
alh1
st-b
rlr?
cmo?
inf
ret
cjc
Advanced Function Setting Level
105.0
0.65
-5.0
15.0
off
off
off
n-o
off
off
off
off
off
off
0.2
0.0
on
a
3
0
Digital Temperature Controllers
MB command logic switching
Input digital filter
Additional PV display
Move to protect level time
Input error output
Cold junction compensation method
Move to calibration level
Parameter initialization
Standby sequence reset method
Alarm 1 open in alarm
ST stable range
MV upper limit
MV lower limit
MV display
Automatic return of display mode
Alarm 1 latch
Multi-SP uses
SP ramp time unit
Alarm 1 hysteresis
Press the
O
key for at least 1 s.
E5GN
Displayed only for models with communications.
Changes are effective after cycling power or
after a software reset.
c
c
u-no
sbit
prty
in-t
in-h
in-l
sl-h
sl-l
cntl
s-hc
c-cp
ore?
alt1
amo?
Communications Setting Level
bps
len
d-u
Moved by setting password ( 169)
cp
dp
st
1300
-200
onof
stnd
or-r
e?en
100
9.6
on
20
20
Initial Setting Level
0
0
0
c
2
0
1
7
2
Stop bits
Baud rate
Data bits
Communications
parity
Input type
Decimal point
Temperature unit
SP lower limit
PID ON/OFF
Standard or heating/cooling
Control period (heating)
Direct/reverse operation
Alarm 1 type
Move to advanced function setting level
Scaling upper limit
SP upper limit
Control period (cooling)
Communications
Unit No.
Scaling lower limit
ST
C, F
Displayed when initial setting/
communications protection is set to 0
CompoWay/F (SYSWAY)
only
Set the pulse output cycle.
For input type of temperature,
standard, or PID
Limit the set point.
Press the
less than 1 s.
(Display flashes for at least 1 s.)
Press the
Displays other than that for switching between
Press the
less than 1 s.
O
O
key
O
key for at least 3 s.
key
automatic and manual