MCR-FL-C-UI-2UI-DCI-NC Phoenix Contact, MCR-FL-C-UI-2UI-DCI-NC Datasheet

no-image

MCR-FL-C-UI-2UI-DCI-NC

Manufacturer Part Number
MCR-FL-C-UI-2UI-DCI-NC
Description
INTERFACE ANALOG
Manufacturer
Phoenix Contact
Datasheet

Specifications of MCR-FL-C-UI-2UI-DCI-NC

Input Type
Configurable
Output Type
Configurable
No. Of Output Channels
2
Accuracy
± 0.15%
Supply Voltage Range
20VDC To 30VDC
Approval Bodies
UL Recognised
External Depth
114.5mm
External Length /
RoHS Compliant
External Length / Height
99mm
External Width
17.5mm
Rohs Compliant
Yes
Signal Multiplier
MCR-FL-C-UI-2UI-DCI
1. Description
to multiply and electrically isolate analog signals.
are electrically isolated from one another (4-way
isolation). In this way, the modules can be used for
electrical isolation, signal conversion, and amplification
both locally and close to the control system. The
auxiliary voltage required is indicated by a green power
LED.
selected within the limits of the order key or for the fixed
signal conversions
provided in the configuration table.
devices are supplied with the default configuration
(input signal 0…20 mA, output signals 0…20 mA/
0…10 V).
as each transmission variant is calibrated and stored in
the device.
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Local Contact: www.phoenixcontact.com/salesnetwork
• 4-way isolation
• Configurable inputs and outputs
• Adjustable signal combinations
• 17.5 mm ME housing
The MCR-FL-C-UI-2UI-DCI signal multiplier is used
The module inputs, outputs, and the power supply
DIP switches can be used to switch between a signal
If no entry is made in the specified order key, the
Adjustment following configuration is not necessary,
Signal conversion and amplification
FL
IN
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
U, I
POWER
U,I
U,I
OUT1
OUT2

Related parts for MCR-FL-C-UI-2UI-DCI-NC

MCR-FL-C-UI-2UI-DCI-NC Summary of contents

Page 1

... U U,I POWER The MCR-FL-C-UI-2UI-DCI signal multiplier is used to multiply and electrically isolate analog signals. The module inputs, outputs, and the power supply are electrically isolated from one another (4-way isolation). In this way, the modules can be used for electrical isolation, signal conversion, and amplification both locally and close to the control system ...

Page 2

... MCR-FL-C-UI-2UI-DCI with configurable input and output Type Preconfigured MCR-FL-C-UI-2UI-DCI Not configured MCR-FL-C-UI-2UI-DCI-NC 0…24 mA/0…12 V, freely selectable in increments of 0.1 (mA/V) 8 mA/4 V, minimum Ω input/200 k Ω input See order key/configuration table ≤ 600 Ω output/ ≥ Ω output 20… ...

Page 3

... B) Warning - explosion hazard - substitution of components may impair suitability for Class 1, Division 2. C) Warning - explosion hazard - do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. MCR-FL-C-UI-2UI-DCI – Signal Multiplier 1 Upper housing part, can be removed to set DIP switches ...

Page 4

... Signal Multiplier – MCR-FL-C-UI-2UI-DCI 3. Configuration 3.1. Opening the Device (Fig. 07) The fastenings on both sides of the upper housing part can be released using a screwdriver 1 . The upper housing part and the electronics can now be pulled out about Ensure you take sufficient measures against electrostatic discharge 3 ...

Page 5

... Signal Multiplier – MCR-FL-C-UI-2UI-DCI 4. Application Example (Fig. 09) Level measurement with ultrasound and subsequent signal multiplication 5. Order Key MCR-FL-C-UI-2UI-DCI The standard configuration will be supplied if customer order details are incorrect or not provided (provided in the order key as an example). Order No. Input Signal Current ...

Related keywords