MCR-FL-C-UI-UI-DCI-24/230 Phoenix Contact, MCR-FL-C-UI-UI-DCI-24/230 Datasheet
MCR-FL-C-UI-UI-DCI-24/230
Specifications of MCR-FL-C-UI-UI-DCI-24/230
Related parts for MCR-FL-C-UI-UI-DCI-24/230
MCR-FL-C-UI-UI-DCI-24/230 Summary of contents
Page 1
... ME Housing POWER 1. Description The configurable MCR-FL-C-UI-UI-DCI-24/230 3-way standard signal isolation amplifier can process 0…20 mA, 4…20 mA and 0…10 V standard signals on the input side. The 3-way isolation between signal input, output and supply is set up as "safe isolation" with a test voltage ...
Page 2
... Configurable 3-Way Isolation Amplifier With Long-Range Power Supply – MCR-FL-C-UI-UI-DCI-24/230 2. Technical Data IN OUT GND GND fixed flexible 2 [mm ] AWG Connection data 0.2-2.5 0.2-2.5 24-14 Description MCR 3-Way isolation amplifier , for electrical isolation of analog signals Technical Data Input Input signal ...
Page 3
... Configurable 3-Way Isolation Amplifier With Long-Range Power Supply – MCR-FL-C-UI-UI-DCI-24/230 Conforms to the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC EMC (electromagnetic compatibility) Noise immunity in accordance with EN 50082-1/EN 50082-2 • Electrostatic discharge (ESD) • Electromagnetic HF field Amplitude modulation Pulsed modulation • ...
Page 4
... Configurable 3-Way Isolation Amplifier With Long-Range Power Supply – MCR-FL-C-UI-UI-DCI-24/230 3. Configuration 3.1. Opening the Device (Figure 06) The locked housing cover is released on both sides using a screwdriver 1 . The housing cover and electronics can now be pulled out 2 . Ensure you take sufficient measures against electrostatic discharge 3 ...