P3-100/EA/SVB MOELLER, P3-100/EA/SVB Datasheet

ISOLATOR, REAR, 100A, 3POLE

P3-100/EA/SVB

Manufacturer Part Number
P3-100/EA/SVB
Description
ISOLATOR, REAR, 100A, 3POLE
Manufacturer
MOELLER
Series
P3r
Datasheet

Specifications of P3-100/EA/SVB

No. Of Poles
3
Contact Voltage Ac Max
690V
Contact Current Ac Max
100A
Svhc
No SVHC (18-Jun-2010)
Current Rating
100A
Power Rating
50kW
Switching Ac3 Power Max
50kW
Voltage
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P3-100/EA/SVB
Manufacturer:
MOELLER
Quantity:
6 000
Part Number:
P3-100/EA/SVB/HI11
Manufacturer:
MOELLER
Quantity:
6 000
Type: P3−100/EA/SVB
Article No.: 074320
Contact sequence
1
Ordering information
Design
Description
Main conducting paths No. of poles
Auxiliary contacts
Auxiliary contacts
Max. three−phase motor rating (per set
of 3 contacts) 50−60 Hz AC−3 400/415
V 50−60 Hz
Rated uninterrupted current
Note for table header
General
Standards
P
I
u
N/O
kW
M
B
A
Flush mounting
Without auxiliary contacts
3
0
0
50
100
According to IEC/EN 60204−1,
VDE 0113 Part 1; with red
rotary handle and yellow
locking collar, lockable in 0
position
IEC/EN 60 947, VDE 0660,
IEC/EN 60 204, CSA,UL
Switch−disconnectors to

Related parts for P3-100/EA/SVB

P3-100/EA/SVB Summary of contents

Page 1

... Type: P3−100/EA/SVB Article No.: 074320 Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts Auxiliary contacts Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415 V 50−60 Hz Rated uninterrupted current Note for table header Contact sequence ...

Page 2

Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Documentation Mechanical shock resistance (shock duration 20 ms) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load−carrying capacity in ...

Page 3

Switching capacity AC Rated making capacity cos = 0.35 Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating ...

Page 4

V Rated operational current Contacts Notes Dimensions Explaination Dimensions Dimensions Quantity 3 Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current I u ...

Page 5

... Characteristic curve Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPL−C2006GB−INT V2.3 5 ...

Related keywords