S3D2CK Omron, S3D2CK Datasheet - Page 5

PHOTOSWITCH CONTROLLER

S3D2CK

Manufacturer Part Number
S3D2CK
Description
PHOTOSWITCH CONTROLLER
Manufacturer
Omron
Datasheet

Specifications of S3D2CK

No. Of Digital Inputs
2
No. Of Digital Outputs
1
Svhc
No SVHC (15-Dec-2010)
Contact Configuration
SPDT
Contact Current Max
3A
External Depth
78mm
External Length / Height
80mm
For Use With
Load Control
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Nomenclature
S3D2-AK/-AKD
* Be sure to set the one-shot timer.
(1)
(2)
(5)
(10)
(11)
(12)
No.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
POWER indicator
IN1 indicator
IN2 indicator
OUT indicator
IN1 input signal selector switch
IN2 input signal selector switch
MODE
(AND/OR operation selector switch)
SYNC
switch)
(This switch is enabled only when
the AND/OR operation selector is
set to AND.)
TIMER switch
RANGE
TIMER MODE
(Timer operation mode switch)
TIME ADJ.
(Timer setting adjuster)
(synchronous mode selector
(Timer timing selector switch)
http://www.ia.omron.com/
Name
(4)
(3)
(6)
S3D2-CK/-CKD/-CC/-CCD
(11)
(2)
(1)
(5)
(7)
(9)
Lights when the operating power is turned ON and the Sensor power supply is output.
Not lit when the operating power is turned OFF, or the Sensor power supply is short circuited
(between the +12-V or +24-V terminal and 0-V terminal).
Lights when the output from the Sensor connected to IN1 is received by IN1 as an input.
Lights when the output from the Sensor connected to IN2 is received by IN2 as an input.
Lights when the output turns ON.
NORM: Input as a signal when the Sensor’s output transistor (or contact output) is ON.
INV:
AND: The output is turned ON when IN1 and IN2 input signals are both ON.
OR: The output is turned ON when either IN1 or IN2 input signal is ON.
Turns timer operation ON/OFF.
ON: Timer enabled
OFF: Timer disabled
Changes the range for the timer setting time.
O. S:
ON. D: ON-delay timer
OFF. D: OFF-delay timer
Setting time can be adjusted with the provided screwdriver.
The adjuster rotates 190 .
S3D2-CK/-EK
S3D2-CC
1 s:
10 s: Setting time is in range from 1 to 10s.
0.1 s: Setting time is in range from 0.01 to 0.1s.
1 s:
: The output is turned ON while both IN1 and IN2 input signals are ON.
: If the input signal of IN2 is turned ON (at the rising edge) while the IN1 input signal is ON, the
(10)
(12)
output is turned
(3)
(4)
(6)
(8)
Input as a signal when the Sensor’s output transistor (or contact output) is OFF.
One-shot timer
Setting time is in range from 0.1 to 1s.
Setting time is in range from 0.1 to 1s.
(1)
(2)
(5)
S3D2-BK
ON.*
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(4)
(3)
(6)
(1)
(5)
Functions
S3D2-DK
(4)
(6)
(12)
(1)
(5)
S3D2-EK
S3D2
(10)
(4)
(6)
(9)
5