N6752A AGILENT TECHNOLOGIES, N6752A Datasheet - Page 10

POWER SUPPLY, BENCH, 50V, 100W

N6752A

Manufacturer Part Number
N6752A
Description
POWER SUPPLY, BENCH, 50V, 100W
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N6752A

Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
50V
Output Current
10A
Power Rating
100W
Input Voltage
100V AC To 240V AC
Length
596.9mm
Width
432.5mm
Height
44.45mm
Lead Free Status / RoHS Status
na
N67xxA Modules:
Readback will not return any
information and errors, such
as -410,“Query INTERRUPTED”
and -420, “Query UNTERMI-
NATED” will be reported.
Multiple, Semicolon-
Separated Queries
The 662xA overwrites any
previous unread query
responses. The N6700A,
however, can respond to
multiple queries.
Example:
VOUT? 1; VOUT? 2; VOUT? 3
<readback>
662xA: Readback returns only
the information for the last
(VOUT? 3) query.
N67xxA Modules: Readback
returns values for all the
queries, separated by
semicolons.
Parameter
Voltage
Current
Reprogramming Delay 20 ms
Store/Recall
Registers
Overvoltage (OV)
Output Channels
OCP Enabled
UNMASK Register
SRQ
Front Panel Metering
Power Supply
Address
Local Control
PON Bit
PON SRQ
Cal Mode
Table 4. Initial Conditions
Numeric Data
662xA: The power supply will
return numeric data (ASCII
characters) in a format that is
dependent on the type of data
requested. Please refer to the
Numeric Data section in the
Remote Operation chapter of
the 662xA Operating Manuals.
N67xxA Modules: Floating-point
numbers returned by the
instrument may not have
exactly the same syntax or
number of digits.
10
40 W/80 W High/Low
Voltage Outputs
0 V
Minimum current limit
0 volts and min.
current limit
23 V on low voltage
outputs and 55 V on
high voltage outputs
On
Off
0 (cleared)
0 (off)
Output #1
Last stored value
(Factory set to 5)
On (enabled)
On
Last stored value
(Factory set to 0)
Off
25 W/50 W
Precision Outputs
0 V High Range
10 mA High Range
20 ms
0 V High Range and
10 mA High Range
55 V (High Range)
On
Off
0 (cleared)
0 (off)
Output #1
Last stored value
(Factory set to 5)
On (enabled)
On
0 (off)
Off
Initial Conditions
If the power supply is not
programmed to recall the
values in the 0 (zero) register
(RCL0), immediately after
power on, the power supply
sets all parameters to their
initial, or “CLR”, values. These
are the values that result from
the “CLR” command.
below lists these parameters
and their initial values.
55 V
N67xxA
Modules
Minimum Voltage
Minimum Current
20 ms
Minimum voltage and
minimum current
Off
0 (off)
0 (cleared)
0 (n/a)
Output #1
Last stored value
(Factory set to 5)
On (enabled)
0 (n/a)
0 (n/a)
0 (off)
Table 4

Related parts for N6752A