XLNPC B&K Precision, XLNPC Datasheet - Page 45

XLN Power Cord

XLNPC

Manufacturer Part Number
XLNPC
Description
XLN Power Cord
Manufacturer
B&K Precision
Datasheet

Specifications of XLNPC

Cable Assembly Type
Power Cord
Equipment Type
Power Cord
Accessory Type
Power Cord
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, na
After wiring is complete, configure one supply as the Master and the other
three as the Slave A, B, and C. After the power supply is configured as Master,
it will start searching for all Slaves that are connected to the Master. Therefore,
in order to setup correctly, user must set up the Slaves before
To set a XLN3640/XLN6024/XLN8018/XLN10014 to the slave mode, press
setting option. Then select the SERIES mode by turning the knob (SCPI
command is “PS:MODE SERIES”) and then press
continue to the next line for the MASTER/SLAVE selection. Turn the knob to
select SLAVE A (SCPI command is “PS:TYPE SLAVEA”) for the instrument
and press
SLAVE B and C for the other two supplies.
To set the master unit, press
enter the series/parallel setting option. Then use the knob to select the series
mode (SCPI command is “PS:MODE SERIES”) and press
It will continue to the next line for the MASTER/SLAVE selection. Use knob
again to select MASTER (SCPI command is “PS:TYPE MASTER”) and then
press
,
to confirm. After confirming the supply as the Master, it will
, and
to confirm the setting. Using the same procedure to set up
L
in the main screen to enter the series/parallel
L
,
38
=
=
L
, and
in the main screen to
to confirm. It will
the Master is set.
to confirm.