CA90/B MTL SURGE TECHNOLOGIES, CA90/B Datasheet - Page 2

AERIAL PROTECTOR

CA90/B

Manufacturer Part Number
CA90/B
Description
AERIAL PROTECTOR
Manufacturer
MTL SURGE TECHNOLOGIES
Series
CAr
Datasheet

Specifications of CA90/B

Suppressor Type
Data Line
No. Of Outlets
1
Outlet Type
BNC
Voltage Rating
90V
Peak Surge Current
10kA
Connector Type
BNC
Clamping Voltage
90V
Clamping Voltage Vc Max
90V
External Depth
60mm
Svhc
No SVHC (15-Dec-2010)
Typical Performance
Limiting voltage
When choosing a surge protection device it is
important to determine the limiting voltage for a
given surge level. Figure 1 shows the effectiveness
of the CA350 series for a 6kV overvoltage. The lim-
iting voltage shows the level of surge ‘let-through’
the surge protection device - in this case just over
600V for a fraction of a microsecond and repre-
sents a very small amount of energy.
Attenuation characteristics
The inclusion of a surge protection device should
have minimal effect on a system other than to
safeguard vulnerable equipment. The attenuation
plot shown in fi gure 2 emphasises how little the
system is changed after fi tting a CA series SPD.
Return Loss
Figure 3 shows the return loss for the N-type vari-
ant of the CA series.
Equivalent circuit
An equivalent circuit model of the CAxx/N is il-
lustrated in fi gure 4. This model gives reasonable
agreement with measured frequency response to
4.2GHz and return loss to 2.5GHz.
Figure 1 Typical limiting voltage for the CA350
Figure 2 Typical attenuation plot for N-type CA devices
Figure 3 Typical return loss for N-type CA devices
Figure 4 Equivalent circuit diagram