DP200/BT MTL SURGE TECHNOLOGIES, DP200/BT Datasheet - Page 2

SURGE PROTECTOR, MODEM/FAX, LIGHTNING

DP200/BT

Manufacturer Part Number
DP200/BT
Description
SURGE PROTECTOR, MODEM/FAX, LIGHTNING
Manufacturer
MTL SURGE TECHNOLOGIES
Series
DP200 BTr
Datasheet

Specifications of DP200/BT

Suppressor Type
Data Line
No. Of Outlets
1
Outlet Type
BT Plug / BT Socket
Voltage Rating
162V
Peak Surge Current
10kA
Connector Type
RJ11
Approval Category
OFTEL
Svhc
No SVHC (15-Dec-2010)
INSTALLATION
In order to mount and earth the unit, the
DP200 BT or RJ must first be opened by
loosening the lid retaining screw and
removing the lid. The unit should be
connected to a good earth point for optimum
protection. This point should be at the mains
distribution board if the telecomms cable runs
close by, otherwise at the mains supply earth
close to the protected equipment.
Connection to this earth point should be made
using 2.5mm
earths should not be ‘daisy-chained’; each
SPD should be earthed separately. Figure 1
shows a complete installation with protection
for both ac power and telecom SPDs fitted.
The earth is taken from the supply to the
telemetry equipment using a short link ( 1m).
The two fixing holes can accommodate either
No.6 or No.8 wood screws or up to 3mm
diameter bolts. The operation of the DP200
BT or RJ is unaffected by its orientation,
although it should not be mounted on a damp
surface. Once the earthing and mounting
operations are complete, the DP200 BT or
RJ is simply re-assembled by fitting the lid
back onto the base and tightening the lid
retaining screw. A comprehensive installation
guide is supplied with each unit.7
SPECIFICATIONS
(all figures typical at 25 C unless otherwise
stated)
Maximum discharge current
Primary protector rating
Working voltage
Max. continuous operating voltage
Leakage current
Ringer Equivalence Number (REN)
Casing
Ambient temperature limits
Humidity
Weight
APPROVALS
Telematic Limited
Pondwicks Road, Luton, Beds, UK LU1 3LH
Telephone: +44 (0)1582 429464 Fax: +44 (0)1582 459669
E-mail: enquiry@telematic.com Web site: http://www.telematic.com
A member of The MTL Instruments Group plc
Model
DP200/BT
DP200/BT/RFI
1 metre. If multiple lines are required, the
10kA
10kV
162V
175V
10 A
0
Plastic ABS - VO IP50 Rated
-40 C to +70 C (working and storage)
5% to 95% RH (non-condensing)
125g nominal
2
wire and should be kept to
(8/20 s)
(10/700 s)
at working voltage
Authority Certificate
BABT
BABT
608379
608379
Line resistance
Limiting voltage
Bandwidth (600 ohms)
Max stopband attenuation
Capacitance
Insertion loss
Line balance 300-3400Hz
Figure 1 Installation using both a DP200/BT and an ac power SPD
Figure 2 Dimensions (mm)
Earth Connection ( 1m)
Telephone connection
AC power supply
6kV/3kA
5kV/125A
line to line
line to earth
at 300Hz
at 3400Hz
Typical values
370 NOM
DP200/BT
Telecom & Data Surge Protection Device
Earth terminal
Made in the U.K.
AC power SPD
Telecom SPD
DP200/BT
MA05/I
110
90
better than 46dB
TELEMATIC LTD, ST.ALBANS, AL4 0XY , UK
TEL +44 (0)1727 833147 FAX +44 (0)1727 850687
& DP200/RJ
DP200/BT
<200pF
<150pF
0.06dB
0.12dB
5 ohms
6MHz
375V
205V
55
Telemetry equipment
& DP200/RJ/RFI
DP200/BT/RFI
better than 46dB
28
maximum
10 ohms
<150pF
0.06dB
<1.5nF
43kHz
250V
205V
65dB
0dB
75

Related parts for DP200/BT