13100044 SCHROFF, 13100044 Datasheet - Page 3

PSU, RACK MODULE, 50W, 12V

13100044

Manufacturer Part Number
13100044
Description
PSU, RACK MODULE, 50W, 12V
Manufacturer
SCHROFF
Datasheet

Specifications of 13100044

Power Supply Type
Switch Mode
Power Supply Output Type
Fixed
No. Of Output Channels
1
Input Frequency
62Hz
Output Voltage
12V
Output Current
4.2A
Power Rating
51W
Input Voltage
90VAC To 264VAC /
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SEK 105
SEK 112
SEK 115
SEK 124
SEK 148
SEK 105
SEK 112
SEK 115
SEK 124
SEK 148
Output OK Signal
100
Strombegrenzung
Current limiting
Limitation de courant
Serienschaltung
Series operation
Branchement en série
Parallelschaltung (CSB)
Parallel operation
Branchement en parallèle
PSU 1
PSU 2
PSU 1
PSU 2
PSU 3
V [ % ]
CSB
11,0
13,9
46,9
4,6
+
+
23
-
-
R
470
1k6
1k6
4k7
20k
V
V
U
pullup
±0,3
±0,2
up
±0,2
±0,2
±0,4
1
1
+
+
+
-
-
-
V
V
V
V
V
I
I
I
1
2
n
10,9
13,7
22,8
45,5
4,5
U
down
±0,2
±0,2
±0,2
±0,3
±0,4
110
V
V
V
V
V
I [ % ]
DIJM0057
Hyst. typ.
200 mV
200 mV
300 mV
600 mV
60 mV
+
+
-
-
+
-
R
R
L
L
Leistungsbegrenzung
Zum Schutz des Gerätes müssen die
maximalen Ausgangsströme mit stei-
gender Temperatur reduziert werden.
Das Derating setzt bei 50 ° C ein.
Strombegrenzung
Die Geräte sind für Dauerkurzschluß
ausgelegt. Der Ausgangsstrom wird
gemäß einer I/U-Kennlinie begrenzt.
Wird die Ausgangsspannung vom
Anwender erhöht, muß er sicherstellen,
daß der maximale Ausgangstrom um
den gleichen Faktor verringert wird.
Das Netzgerät kann sonst zerstört wer-
den.
Beispiel: U
Überspannungsschutz
Der OVP ist werkseitig eingestellt
(siehe technische Daten). Beim
Ansprechen des Überspannung-
schutzes wird der Regler abgeschaltet.
Wenn die Überspannung nicht mehr
ansteht schaltet sich das Netzgerät
wieder ein.
Serienschaltung
Sehen Sie am Ausgang externe Invers-
dioden vor. Summenspannung von
200 V nicht überschreiten. Spricht bei
einem Gerät die Strombegrenzung an,
muß die Last kurz abgetrennt werden.
Bei Serienschaltung können am Aus-
gang berührungsgefährliche Spannun-
gen auftreten:
SELV-Spannung nur bis 60 V
Parallelschaltung
Zur Leistungserhöhung oder Redun-
danzbetrieb werden die Ausgänge der
Netzgeräte parallel verbunden. Es
erfolgt eine geregelte Lastaufteilung
wenn der Current Share Bus der Netz-
geräte miteinander verbunden ist (Pin
22, max. 12 Geräte parallelschaltbar,
max. Ausgangsleistung ca. 0.9*P
Damit im Redundanzbetrieb alle Netz-
geräte arbeiten ist eine Grundlast von
0,1*P
Die Entkoppeldiode ist eingebaut.
Netzspannung
Die Power Supplies haben einen Weit-
bereichseingang (90 V
130 V
Output OK Signal
Das Output OK Signal zeigt an, ob die
Ausgangsspannung vorhanden ist
(siehe Diagramm Output OK Signal).
Der Pullup Widerstand ist eingebaut.
Garantiebedingungen
Leistungsdauer
Für dieses Produkt leisten wir 2 Jahre Garantie.
Der Anspruch beginnt mit dem Tage der
Auslieferung.
Umfang der Mängelbeseitigung
Innerhalb der Garantiezeit beseitigen wir kostenlos
alle Funktionsfehler am Produkt, die auf mangelhafte
Ausführung bzw. Materialfehler zurückzuführen sind.
Weitergehende Ansprüche – insbesondere für
Folgeschäden – sind ausgeschlossen.
Garantieausschluß
Schäden und Funktionsstörungen verursacht durch
Nichtbeachten unserer Bedienungsanleitung sowie
Fall, Stoß, Verschmutzung oder sonstige unsach-
gemäße Behandlung fallen nicht unter die Garantie-
leistung.
Die Garantie erlischt, wenn das Produkt von
unbefugter Seite geöffnet wurde. Eingriffe erfolgt
sind oder die Seriennummer am Produkt verändert
oder unkenntlich gemacht wurde.
Abwicklung des Garantieanspruches
Das vorliegende Produkt wurde sorgfältig geprüft
und eingestellt.
Bei berechtigten Beanstandungen schicken Sie uns
das Produkt bitte zurück. Zur Erhaltung Ihres
Garantieanspruches beachten Sie bitte folgendes:
Legen Sie eine möglichst genaue Beschreibung
des Defektes bei.
Das Produkt ist im Original-Karton oder gleich-
wertiger Verpackung einzusenden und zwar
versichert und portofrei.
max
DC
– 340 V
erforderlich.
DC
+ 10 % => I
DC
).
AC
DC
– 264 V
- 10 %.
DC
.
AC
max.
,
).
Output power Limiting
In order to protect the unit the maximum
output currents reduced as the
temperature increases. Derating is
activated at 50 ° C.
Current limiting
The power supply features short-circuit
protection. The output current is limited
according to an I/V curve. If the output
voltage is increased by the user, the
maximum output current must be
reduced by the same factor. The power
supply may otherwise be destroyed.
Example: V
Over-voltage protection
The OVP is pre-set (see technical data).
When the over-voltage protection is
triggered the regulator is switched off.
The unit is automatically reset when
there is no longer any over-voltage.
Series operation
External inverse diodes should be used
at the output. Do not exceed a total
voltage of 200 V. If the current limiting is
triggered in a unit the load should be
removed briefly. Dangerous voltages
may occur at the output with series
operation:
SELV voltage only up to 60 V
Parallel operation
The unit outputs are set up for parallel
operation to increase the output power
or for redundancy. The load share
control operates if the Current Share
Buses of the unit are linked together(Pin
22 max 12 units). max. output
performance approx. 0.9*P
all power supplies work in redundancy
mode, a basic load of 0.1*P
required.
The decoupling diode is built in.
Mains/line voltage
The power supplies have a broad
range input (90 V
– 340 V
Output OK Signal
The Output OK Signal is on if there is an
existing output voltage(see diagram
Output OK Signal).
The pullup resistor is build in.
Warranty conditions
Duration
This product has a warranty of 2 years.
The warranty begins on the day of delivery
Cover of defects
Within the warranty period Schroff will repair free of
charge any faulty functioning of the product
resulting from faulty design or defective material.
All other claims under the warranty are excluded, in
particular consequential damage.
Warranty exclusion
The warranty does not cover damage or functional
defects caused by non-adherence to the
Company´s operating instructions or such caused
by dropping, knocking, contamination or other
untoward handling. The warranty is invalidated if
the product is opened by unauthorized personnel,
tampered with or the serial number on the product
has been changed or rendered illegible.
Claims under warranty
This product has been carefully checked. If you
have a valid claim, please return the product to
SCHROFF. In order to make a claim under the
warranty, ensure that the following is carried out:
Include a detailed description of the fault.
The product should be returned in the original
carton or similar packaging, insured and
post paid.
DC
).
DC
+ 10 % => I
AC
– 264 V
DC
max.
AC
max
- 10 %.
DC
, 130 V
.
So that
is
DC
Limitation de puissance
Afin de protéger l’alimentation, les
courants de sortie max. diminuent á
mesure que la température augmente.
Le derating démarre à 50 °C.
Limitation de courant
Les alimentations sont conçues pour
pouvoir supporter un court-circuit
permanent. Le courant des sortie est
régulé selon une courbe caractéristique
I/V. Si l’utilisateur accroît la tension de
sortie, il doit veiller à réduire le courant
maximal de sortie dans la même
proportion, sinon l’alimentation risque
d’être détériorée.
Exemple: U
Protection aux surtensions
L’OVP est prérèglé en usine (voir
Caractéristiques Techniques). Dans le
cas du déclenchement de la protection
aux surtensions, l’alimentation est
arrêtée. Lorsque la surtension disparait,
l’alimentation se remet en marche.
Branchement en série
Il faut prévoir des diodes de protection
contre les inversions de polarité. Ne pas
dépasser la tension totale de 200 V.
Lorsque l’un des appareils déclenche en
limitation de courant, il faut déconnecter la
charge pendant un court moment. Lors
d’une mise en série, des tensions
dangereuse peuvent apparaître à la
sortie:
tension SELV uniquement jusqu’à 60 V
Branchement en parallèle
Pour accroitre la puissance ou pour une
utilisation en redondance des
alimentations les sorties seront reliées en
parallèle. Une répartition autonome de la
charge est assurée lorsque les sorties
Current Share Bus des alimentations sont
reliées entre elles (broche 22, max. 12
alimentations en parallèle, tension max.
de sortie env. 0.9*P
de redondance toutes les alimentations
soient en service il faut une charge
minimale de 0,1*P
La diode de découplage est intégrée.
Adaptation de la tension secteur
L´alimentation dispose d´une plage
d´entrée secteur étendue. Elle s´adapte
automatiquement à la tension secteur
(90 V
Signal Output OK
Le signal Output OK indique la présence
ou non de la tension de sortie (voir
schéma Signal Output OK). La résistante
Pullup est intégrée.
Garantie
Garantie contractuelle
Les conditions d‘applications de la garantie, et en
particulier la durée, l‘étendue et les cas d‘exclusion,
figurent dans nos conditions générales de ventes,
paragraphe 11 „Garantie contractuelle“.
Application de la garantie
Cette alimentation a été soigneusement contrôlée en
usine. En cas de réclamations, veuillez nous la
retourner accompagnée d‘une description la plus
précise possible du défaut constaté, et d‘une copie du
bon de livraison ou de la facture. Le produit doit nous
être retourné dans son emballage d‘origine port
assuré et payé.
Schroff n‘assume aucune responsabilité pour des
appareils non assurés et endommagés pendant le
transport.
AC
– 264 V
DC
+ 10 % => I
AC
, 130 V
max
max
.
). Pour qu’en mode
DC
DC
– 340 V
- 10 %.
DC
).
DC
.

Related parts for 13100044