LS100-3.3 TDK Corporation, LS100-3.3 Datasheet - Page 2

AC-DC, 115-230VAC, Output 3.3V 20A, 66W

LS100-3.3

Manufacturer Part Number
LS100-3.3
Description
AC-DC, 115-230VAC, Output 3.3V 20A, 66W
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS100-3.3

Voltage - Output
3.3V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 20A
Size / Dimension
6.3" L x 3.8" W x 1.5" H (160mm x 96.5mm x 38.1mm)
Power (watts) - Rated
66W
Operating Temperature
-25°C ~ 70°C
Efficiency
75%
Approvals
CE, EN, IEC, UL
Brand/series
LS Series
Configuration
Enclosed
Current, Output
20.0
Frequency, Input
47-63 Hz
Height
1.5 Inch
Length
6.3 Inch
Line Regulation
20 mV
Load Regulation
40 mV
Operation
Switching
Output
3.3 VDC @ 20 A
Power Rating
66 Watts
Power, Output
66 W
Primary Type
AC-DC
Ripple, Rejection
80 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
3.00-3.60
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
3.3 VDC
Weight
21.5 Ozs.
Width
3.8 Inch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1807
LS1003
LS1003.3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS100-3.3
Manufacturer:
TDK-LAMBDA
Quantity:
617
1. Terminal Explanation
LS25, LS35, LS50, LS75
(1) L : Input terminal
(2) N : Input terminal
(3) FG
(4) - V : - Output terminal
(5) +V : + Output terminal
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
LS100, LS150
(1) L : Input terminal
(2) N : Input terminal
(3) FG
(4) -V : - Output terminal
(5) +V : + Output terminal
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
2. Terminal connecting method
Maximum output current of each output terminal is 25A except for LS25 (15A).
If more than 25A, use 2 terminals.
LOAD
( 25A max./ terminal)
( 25A max./ terminal)
Input must be off when making connection.
Connect FG terminal to ground terminal of the equipment.
The output load line and input line shall be separated and twisted to improve noise immunity.
-
+
LS25, LS35, LS50, LS75
: Functional Ground
: Functional Ground
Live line (Fuse in line)
Live line(Fuse in line)
Neutral line
Neutral line
1
LOAD
-
+
LS100, LS150
LS
INSTRUCTION MANUAL
TDK-Lambda
25-150
Series
1
2
3
4
5
1
2
3
4
5
6
7

Related parts for LS100-3.3