LS100-3.3 TDK Corporation, LS100-3.3 Datasheet - Page 5

AC-DC, 115-230VAC, Output 3.3V 20A, 66W

LS100-3.3

Manufacturer Part Number
LS100-3.3
Description
AC-DC, 115-230VAC, Output 3.3V 20A, 66W
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS100-3.3

Voltage - Output
3.3V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 20A
Size / Dimension
6.3" L x 3.8" W x 1.5" H (160mm x 96.5mm x 38.1mm)
Power (watts) - Rated
66W
Operating Temperature
-25°C ~ 70°C
Efficiency
75%
Approvals
CE, EN, IEC, UL
Brand/series
LS Series
Configuration
Enclosed
Current, Output
20.0
Frequency, Input
47-63 Hz
Height
1.5 Inch
Length
6.3 Inch
Line Regulation
20 mV
Load Regulation
40 mV
Operation
Switching
Output
3.3 VDC @ 20 A
Power Rating
66 Watts
Power, Output
66 W
Primary Type
AC-DC
Ripple, Rejection
80 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
3.00-3.60
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
3.3 VDC
Weight
21.5 Ozs.
Width
3.8 Inch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1807
LS1003
LS1003.3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS100-3.3
Manufacturer:
TDK-LAMBDA
Quantity:
617
4. Isolation / Withstand Voltage
4-1. Isolation Test
Isolation resistance between output and FG (chassis) shall be more than 100MΩ at 500VDC. For safety, voltage setting
of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test.
4-2. Withstand Voltage
This series is designed to withstand 3.0kVAC between input and output, 1.5kVAC between input and FG (chassis) and
500VAC between output and FG (chassis) each for 1 minute. When testing withstand voltage, set current limit of with-
stand voltage test equipment at 20mA ( Output-FG (chassis) : 100mA ). The applied voltage must be gradually increased
from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be
damaged by high impulse voltage at timer switch on and off. Connect input and output as follows :
(a) Input ~ FG (chassis) : solid line
(b) Input ~ Output : dotted line
1.5kVAC, 1min (20mA)
3kVAC, 1min ( 20mA )
(a) Output ~ FG (chassis) : 500VDC, 100MΩ or more
Isolation
Tester
Withstand
Voltage
Tester
AC(L)
AC(N)
FG
AC(L)
AC(N)
FG
+ V
- V
+V
- V
+V
+V
-V
-V
4
Withstand
Voltage
Tester
(c) Output ~ FG (chassis) : 500VAC, 1min (100mA)
FG
AC(L)
AC(N)
LS
INSTRUCTION MANUAL
TDK-Lambda
25-150
Series
+V
+V
-V
-V

Related parts for LS100-3.3