OKX-T/10-W5P-C Murata Power Solutions Inc, OKX-T/10-W5P-C Datasheet
OKX-T/10-W5P-C
Specifications of OKX-T/10-W5P-C
Related parts for OKX-T/10-W5P-C
OKX-T/10-W5P-C Summary of contents
Page 1
... See specifi cations. For full details go to Adjustable DOSA 10/16-Amp SIP DC/DC Converters The OKX-T/10 and -T/16 series are miniature SIP non-isolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi ...
Page 2
The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ...
Page 3
TYP 4.45 .175 10.16 .400 RECOMMENDED FOOTPRINT -TOP VIEW 50.8 2.00 12.7 . 2.54 .100 TYP 12.70 35.56 .500 1.400 MATERIAL: PINS: ...
Page 4
... Output 9* *Sequence/Tracking 5 Common 10 11 On/Off Control *Sequence/Tracking is standard for OKX2. On OKX models, Pin 9 is omitted. Dimensions are in inches (mm shown for ref. only). Tolerances (unless otherwise specified): 0.76 .XX ± 0.02 (0.5) .030 .XXX ± 0.010 (0.25) TYP Angles ± 1˚ 1.27 ...
Page 5
... Vout=nominal Isolation Not isolated Safety Designed to meet UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1 Calculated MTBF per Telcordia SR-232 (4a) 6.54 mHRS (OKX2-T/16-D12P) Calculated MTBF per MIL-HDBK-217F (4b) 5.3 mHRS (OKX2-T/16-D12P) Output Voltage Range See Ordering Guide Minimum Loading No minimum load Accuracy (50% load, untrimmed) ± ...
Page 6
If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse prevents overheating and damaging the ...
Page 7
Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. We recommend a time delay fuse ...
Page 8
In the fi gure, the two copper strips simulate real-world printed circuit impedances between the power supply and its load. In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or ...
Page 9
On the input side, a remote On/Off Control can be ordered with either polarity. Please refer to the Connection Diagram on page 1 for On/Off connections. Positive polarity models are enabled when the On/Off pin is left open or is ...
Page 10
... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 1.5V) OUT 12V 14V www.murata-ps.com (V = 12V ...
Page 11
... 14V Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT 12V 14V OKX2-T/10-D12-C Maximum Current Temperature Derating at Sea Level 11 10.5 10 9 www ...
Page 12
... PERFORMANCE DATA OKX2-T/10-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 5V) OUT 8. 12V 14V OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 0.7525V) OUT 8. 12V 14V OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=0.75V, Iout=16A, Cin=1000μF, Cload=1μF // 10μF, ScopeBW=100MHz) ...
Page 13
... V = 12V 14V OKX2-T/16-D12 Step Load Transient Response (Vin=12V, Vout=1.5V, Cin=1000μF, Cload=0, Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=1.5V, Iout=16A, Cin=1000μ Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div., Trace4=Iout, 5A/div. ...
Page 14
... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level 17 16.5 16 15.5 15 14.5 14 13.5 13 12.5 12 11.5 11 10 OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 2.5V) OUT 12V 14V OKX2-T/16-D12-C Maximum Current Temperature Derating at Sea Level 17 16 ...
Page 15
... PERFORMANCE DATA OKX2-T/16-D12 Output Ripple and Noise (Vin=12V, Vout=3.3V, Iout=16A, Cin=1000μF, Cload=1μF // 10μF, ScopeBW=100MHz) OKX2-T/16-D12 Effi ciency vs. Line Voltage and Load Current @ +25° 5V) OUT 8. 12V 14V Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C Step Load Transient Response (Vin=12V, Vout=3.3V, Cin=1000μF, Cload=0, Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div ...
Page 16
... ISO 9001 and 14001 REGISTERED Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-D12-C On/Off Enable Startup Delay (Vin=12V, Vout=5V, Iout=16A, Cin=1000μF, Iout=8A to 16A to 8A) Trace1=Vout, 200 mV/div., Trace4=Iout, 5A/div. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi ...