OKX-T/10-W5P-C Murata Power Solutions Inc, OKX-T/10-W5P-C Datasheet
OKX-T/10-W5P-C
Specifications of OKX-T/10-W5P-C
Related parts for OKX-T/10-W5P-C
OKX-T/10-W5P-C Summary of contents
Page 1
... See specifi cations. For full details go to Adjustable DOSA 10/16-Amp SIP DC/DC Converters The OKX-T/10 and -T/16 series are miniature SIP non-isolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi ...
Page 2
The input voltage range must be 0.5V greater than the output voltage. ② All specifications are at nominal line voltage, ...
Page 3
TYP 4.45 .175 10.16 .400 RECOMMENDED FOOTPRINT -TOP VIEW 50.8 2.00 12.7 . 2.54 .100 TYP 12.70 35.56 .500 1.400 MATERIAL: PINS: ...
Page 4
... Output 9* *Sequence/Tracking 5 Common 10 11 On/Off Control *Sequence/Tracking is standard for OKX2. On OKX models, Pin 9 is omitted. Dimensions are in inches (mm shown for ref. only). Tolerances (unless otherwise specified): 0.76 .XX ± 0.02 (0.5) .030 .XXX ± 0.010 (0.25) TYP Angles ± 1˚ 1.27 ...
Page 5
... Positive Logic (“P” model suffi Open pin (internally pulled up) or +1.5V to +Vin max. OFF = Ground pin to +0.4V. max. Current 1 mA max. Tracking/Sequencing (OKX “2” models) Slew Rate 2 Volts per millisecond, max. Tracking accuracy, rising input Vout = ±200 mV max. of Sequence In Tracking accuracy, falling input Vout = ± ...
Page 6
All models are fully operational and meet published specifications, including “cold start” at –40°C. (10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. ...
Page 7
Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a ...
Page 8
COPPER STRIP +SENSE +OUTPUT C1 -OUTPUT COPPER STRIP C1 = 0.1μF CERAMIC C2 = 10μF TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 3: Measuring Output Ripple and Noise (PARD the shutdown temperature, an on-board electronic temperature sensor ...
Page 9
Dynamic control of the On/Off function must sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a fi nite time in milliseconds (see Specifi cations) between the time of ...
Page 10
... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX-T/10-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 OKX-T/10-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 OKX-T/10-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 www.murata-ps.com (V = 2.5V) OUT 5.5V ...
Page 11
... Vout=1.5V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div. In this graphic data, 10 Amp models perform identically to 16 Amp models with the limitation of 10 Amps output. Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/10-W5 Maximum Current Temperature Derating at Sea Level = 5.0V 0.75 to 3.3V. For V = 3.3V 0.75 to 2.5V. Longitudinal airfl ...
Page 12
... Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 OKX-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 OKX-T/16-W5 Effi ciency vs. Line Voltage and Load Current @ +25°C 100 www.murata-ps.com (V = 2.5V) OUT ...
Page 13
... V Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Adjustable DOSA 10/16-Amp SIP DC/DC Converters OKX2-T/16-W5 Maximum Current Temperature Derating at Sea Level = 5.0V 0.75 to 3.3V. For V = 3.3V 0.75 to 2.5V. Longitudinal airfl ow.). ...