QO112M100 SQUARE D, QO112M100 Datasheet - Page 25

CIRCUIT BREAKER, LOAD CENTER, 240V, 100A

QO112M100

Manufacturer Part Number
QO112M100
Description
CIRCUIT BREAKER, LOAD CENTER, 240V, 100A
Manufacturer
SQUARE D
Series
QOr
Datasheet

Specifications of QO112M100

Supply Voltage
240VAC
Current Rating
100A
No. Of Branch Circuits
12
External Depth
3.75"
External Height
17.92"
External Width
14.25"
Enclosure Material
Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
03/2007
1
2
3
4
5
6
A UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with factory-installed service disconnect.
B UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with field-installed service disconnect.
C UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) when not more than six service disconnecting means are provided and when not
D UL Listed as suitable for use as service equipment (neutral bonded at the time of installation) with field-installed main lugs and not more than six service disconnecting means
Load Center with Cover – 1-Phase, 3-Wire, 120/240 Vac – UL Listed; Complete QO
Convertible Mains – Factory-Installed Main Lugs; QOM1 Main Frame Size – Convertible to Main Circuit Breaker – Copper Bus
Convertible Mains – Factory-Installed Main Lugs; QOM2 Main Frame Size – Convertible to Main Circuit Breaker – Copper Bus
Convertible Mains – Factory-Installed Main Circuit Breaker – 22,000 RMS Symmetrical Amperes Short Circuit Current Rating
QOM1 Main Frame Size – Convertible to Main Lugs – Copper Bus
Convertible Mains – Factory-Installed Main Circuit Breaker – 22,000 RMS Sym. Amperes Short Circuit Current Rating
QOM2 Main Frame Size – Convertible to Main Lugs – Copper Bus
Non-Metallic 1-Phase, 3-Wire, 120/240 Vac – Main Lugs Only
Riser , 1-Phase, 3-Wire, 120/240 Vac – Factory-Installed Main Lugs – Offset Interior Wide Gutter QOM1/QOM2
Generator Panel, 1-Phase, 3-Wire, 120/240 Vac – Factory-Installed Main Circuit Breakers with Mechanical Interlock
Generator Panel - Use with Automatic Transfer Switch, 1-Phase, 3-Wire, 120 / 240 Vac, Factory- / Field-Installed Main Circuit Breaker –
22,000 RMS Sym. Amperes Short Circuit Current Rating
Rating
Mains
Amps
200 A
125
150
200
100
150
125
200
150
200
225
150
200
Short circuit current rating depends on lowest AIR rating of main or branch circuit breaker installed.
22,000 A rms symmetrical maximum when supplied by integral type QOM-VH main circuit breaker from Square D
and when all installed QO
UL Listed for 5000 A rms symmetrical short circuit rating when used in 3-phase, 240 Vac, corner grounded Delta systems, when used as main lugs load center only. Use QO-
H 240 Vac circuit breakers only.
QOM2 Load Center is ONLY convertible to main circuit breaker when used with QOC cover.
One main circuit breaker is included with panel. Alternate source main circuit breaker (QO 125 A max.) must be ordered separately. Automatic transfer switch and generator kit
for secondary power sources are ordered through a Kohler
Side-hinge door device allow 1.25 in. (32mm) on the left side for the door to open.
used as a lighting and appliance branch circuit panelboard. See NEC Article for Lighting and Appliance Branch Circuit Panelboard.
are provided and when not used as a lighting and appliance branch circuit panelboard. See NEC Article for Lighting and Appliance Branch Circuit Panelboard.
60
30
60
in
QO112L125GC
QO11224L125GC
QO120L125GC
QO130L150TC
QO13040L200GC
QO112M100C
QO11220M100C
QO116M100C
QO120M100C
QO12030M150C
QO130M150C
QO12040M200C
QO130M200C
QO13040M200C
QO140M200C
QO24L60NRNM
QO11224L125WG
QO12030L125WG
QO13040L200WG
QO48M30DSGP
QO48M60DSGP
QO13842MX150
QO13842MX200
QO13842MX225
QO13842UX225
QO11428MX150FTRB
QO11428MX200FTRB
QO11428UX200FTRB
Catalog Number
Load Center
®
branch circuit breakers have 10,000 A rms symmetrical minimum interrupting rating.
6
6
6
QOC20UFWG
QOC38MXUF
Load Center
QOC30UFW
Number
Catalog
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Cover
UL Listed Service
(See Notes)
Equipment
®
B, C
B, C
B, C
B, C
B, C
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
B, C
B, C
B, C
No
authorized dealer or contractor.
B
A
A
A
A
B
A
A
B
5
QO
Circuit Rating
Maximum UL
65,000 A
65,000 A
65,000 A
65,000 A
65,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
65,000 A
65,000 A
10,000 A
65,000 A
10,000 A
10,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
22,000 A
Short
®
and Homeline
2 3
2 3
2 3
2 3
2 3
2
2
2
2
2
2
2
2
2
2
2
2
1
®
Load Center – Box, Interior and Combination Cover (in one package)
Main Wire Size
AWG/kcmil
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 50
#4 2 /0
#4 2 /0
#4 2 /0
#4 2 /0
#4 2 /0
#4-250
#4-250
#4-250
#4-250
#4-250
#4-250
#4-250
#4-1/0
#4-1/0
#4-1/0
#4-1/0
Al/Cu
#14 4
#14 8
4
#8 2
Main Frame Size – Convertible to Main Circuit Breaker – Copper Bus
© 2007 Schneider Electric All Rights Reserved
®
®
with 22,000 A rms symmetrical minimum interrupting rating
Load Centers and Enclosures
Enclosure
(Pages 26
and 27)
1NM
No.
7R
7R
7R
10
14
14
23
12
12
12
12
6
6
7
9
9
5
5
6
6
9
9
9
9
9
4
4
Mains Position
Top or Bottom
Technical Information
Bottom
Bottom
Bottom
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Corner Grounded
Delta Systems
UL Listed for
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
3
25

Related parts for QO112M100