JDL26250 SQUARE D, JDL26250 Datasheet - Page 45

CIRCUIT BREAKER, THERMAL MAG, 2P, 250A

JDL26250

Manufacturer Part Number
JDL26250
Description
CIRCUIT BREAKER, THERMAL MAG, 2P, 250A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of JDL26250

Actuator Style
Toggle
No. Of Poles
2
Current Rating
250A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12/08
Motor Type / Tipo de Motor / Type de Moteur
Standard
Energy Efficient
Energie Efficace
Energia Eficiente
Sta nd
En erg
En erg
En erg
ard
y Eff
ie Eff
ia Efi
ici en
ica ce
cie nte
t
t
Standard
Energy Efficient
Energie Efficace
Energia Eficiente
PowerPact
I
®
H- and J-frame Electronic Motor Circuit Protectors
PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only
instantaneous-trip circuit breakers. They are designed to offer short circuit protection and
are National Electrical Code (NEC) compliant when installed as part of a combination
controller having motor overload protection. MCP circuit breakers accept the same
accessories and terminals as the equivalent thermal-magnetic circuit breakers.
Determine the hp rating from the nameplate of the motor. Select a MCP with an ampere
rating recommended for the hp and voltage involved. When using the automatic settings
the MCP microprocessor automatically adjusts the trip settings for both current and time to
align with the start-up characteristic for the motor type, whether it is a standard or energy-
efficient motor. This includes a dampening means to accommodate a transient motor in-
rush current without nuisance tripping of the circuit breaker.
H- and J-frame Electronic Motor Circuit Protectors (MCP)
Maximum Rating or Setting of Motor Protective Devices
MCP Selection by HP Ratings
Wound-rotor Motors
Short Circuit Current Rating (SCCR)
Tested to meet NEC and UL508A requirements for short circuit current ratings as part of
an approved combination controller.
Short Circuit Current Ratings (SCCR)
H-frame
J-frame
Frame
Tesys D-line and F-line
200 Vac
Contactor/Starter
10–25
20–40
40–60
5–10
Based on 2005 NEC Table 430.52.
See NEC Exception No. 1 to Table 430.52. The NEC 1300% maximum setting may be inadequate for
instantaneous trip circuit breakers to withstand current surges typical of the magnetization current of
autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from “start” to
“run,” constant hp multi-speed motors, and motors labeled “high efficiency.”
.5–5
Based on 2005 NEC Table 430.250.
Per NEC 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the
allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a
disconnecting means per NEC 430.103.
Listed voltages are rated motor voltages. Corresponding system voltages are 200 Vac, 220–240 Vac, 440–480
Vac and 550–600 Vac. Select wire and circuit breakers based on horsepower rather than nameplate full-load
current per NEC 430.6 (A) for general motor applications.
NEMA Type S
A, B, C, D
B, E
Current
100 A
150 A
250 A
30 A
50 A
Type of Motor
114–217 A
230 Vac
Full Load
Amperes
58–130 A
1.5–25 A
14–42 A
30–80 A
.5–7.5
15–30
25–50
50–75
5–15
Range
3Ø 60 Hz Voltages
200–240 Vac
100 kA
100 kA
Energy Efficient
Instantaneous
180–1040 A
348–1690 A
684–2500 A
Adjustable
Trip Range
Standard
84–546 A
9–325 A
Moulded Case Circuit Breakers
100–150
460 Vac
50–100
.75–15
10–30
25–60
J Interrupting
of Induction-type Squirrel-Cage and
480 Vac
65 kA
65 kA
Suffix
M71
M72
M73
M74
M75
125–200
575 Vac
60–125
15–40
30–75
1–20
600 Vac
(See SCCR Table Below)
HJL36030M71
HJL36050M72
HJL36100M73
HJL36150M74
JJL36250M75
25 kA
25 kA
Cat. No.
J Interrupting
Setting
1100%
800%
Percentage of Full-load Current
200–240 Vac
Full-Load Amperes
125 kA
125 kA
$ Price
114–217
58–130
1.5–25
14–42
30–80
L Interrupting
(See SCCR Table Below)
HLL36030M71
HLL36050M72
HLL36100M73
HLL36150M74
JLL36250M75
480 Vac
100 kA
100 kA
Magnetic Trip
Not to Exceed
Cat. No.
L Interrupting
1300%
1700%
DE3-45
Suffix
M71
M72
M73
M74
M75
600 Vac
50 kA
50 kA