TIMING SPECIFICATIONS FOR STROBE & DATA INPUTS
CONNECTIONS
Also cabling should conform to appropriate standards of good installation, local
codes and regulations. It is recommended that power supplied to the unit be
protected by a fuse or circuit breaker.
Four optional accessory boards (Model ATB1, ATB2, ATB3 and ATB4) provide
screw clamp terminals for easy wire termination and DIP sockets for ease of
cascading displays. Models ATB1 and ATB3 have screw clamp terminations for
all input connections. Models ATB2 and ATB4 have screw clamp terminations for
all inputs except the BCD Data Inputs. ATB2 and ATB4 are used when the BCD
data lines are to be cascaded to other units using the DIP Plug Cable Assembly.
The preceding drawings show all accessory boards being utilized in a system.
(Model ACE4) for 5 and 6 digit slaves, provide another way to make
connection. These edgecard connectors have 0.156" center to center spacing and
require the soldering of the wires to the connector for wire termination. The
diagram above shows edgecard connectors being used with the Slave Display.
All conductors should meet voltage and current ratings for each terminal.
There are several different ways to make connections to the Slave Display.
An optional 24-pin (Model ACE1) for 3 and 4 digit slaves and 24 & 12-pin
Note: Specifications shown are based on a sourcing input with V
equal to 100% and 0% of power supply respectively.
fscan max.
tdsu min.
tws min.
tdh min.
tcy min.
=
=
=
=
=
5 µs (strobe pulse width)
1 µs (data set-up time)
5 µs (data hold time)
10 µs (cycle time)
1/tcy min. = 100 KHz (scan rate)
IH
and V
IL
levels
4
EDGECARD CONNECTOR PIN-OUTS
MODEL APLSP3A: “5 VDC VERSION”
MODEL APLSP4A: “5 VDC VERSION”
MODEL APLSP5A: Bottom Connector
MODEL APLSP6A:
MODEL APLSP5A-B: Top Connector
*
**
Apply power on A and C or E and C.
When “LT” (LAMP TEST) is connected to “COMM.” the unit will display all 8’s.
MODEL APLSP3B: “10 to 28 VDC VERSION”
MODEL APLSP4B: “10 to 28 VDC VERSION”
MODEL APLSP5B: Bottom Connector
MODEL APLSP6B:
MODEL APLSP6A-B: Top Connector