AFCT-701SDDZ Avago Technologies US Inc., AFCT-701SDDZ Datasheet - Page 10

no-image

AFCT-701SDDZ

Manufacturer Part Number
AFCT-701SDDZ
Description
10G/1G Dual Data Rate SFP+LR,RoHS
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of AFCT-701SDDZ

Data Rate
10.312Gbd
Wavelength
1310nm
Applications
Ethernet
Voltage - Supply
3.135 V ~ 3.465 V
Connector Type
LC Duplex
Mounting Type
SFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 5. Low Speed Signal Electrical Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Typical values are for Tc = 40°C. VccT and VccR = 3.3 V.
Parameter
Module Supply Current
Power Dissipation
TX_FAULT, RX_LOS
TX_DISABLE
Notes:
1. Supply current includes both VccT and VccR connections.
2. Measured with a 4.7 k: load to VccHost.
3. TX_DISABLE has an internal 4.7 k: to 10 k: pull-up to VccT
Table 6. High Speed Signal Electrical Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Tx Input Differential Voltage, |(TD +) - (TD-)|
Tx Input AC Common Mode Voltage Tolerance
Tx Input Differential S-parameter (100 : Ref.)
Tx Input Reflected Differential to
Common Mode Conversion (25 : Ref.)
Rx Output Differential Voltage, |(RD +) - (RD-)|
Rx Output Termination Mismatch @ 1MHz
Rx Output AC Common Mode Voltage
Rx Output Output Rise and Fall Time
(20% to 80%)
Rx Output Total Jitter
Rx Output 99% Jitter
Rx Output Differential S-parameter (100 : Ref.)
Rx Output Common Mode Reflection
Coefficient (25 : Ref.)
Receiver Output Eye Mask
Notes:
1. Internally AC coupled and terminated (100 Ohm differential).
2. Internally AC coupled but requires an external load termination (100 Ohm differential).
3. Reflection Coefficient given by equation SDD11(dB)=Max(-12 + 2*SQRT(f ) -6.3+13Log10(f/5.5)), with f in GHz.
4. Differential Output S-parameter given by equation SDD22(dB)= Max(-12 + 2*SQRT(f ) -6.3+13Log10(f/5.5)), with f in GHz.
5. The RMS value is measured by calculating the standard deviation of the histogram for one UI of the common mode signal.
6. TJ conditions per SFF-8431
10
Symbol
I
P
I
V
V
V
Symbol
V
SDD11
SCD11
Vo
'Z
tr, tf
TJ
DJ
SDD22
SCC22
CC
OH
DISS
OL
IH
IL
I
m
Minimum
- 50
-
2.0
-0.3
Minimum
180
300
28
0.3
Typical
258
850
Typical
Note 3
Note 4
-6
-3
Maximum
289
1000
+ 37.5
0.4
VccT + 0.3
0.8
Maximum
700
15
-10
850
5
7.5
0.70
0.332
0.42
Unit
mA
mW
PA
V
V
V
Unit
mV
mV(RMS)
dB
dB
mV
%
mV(RMS)
ps
Ulp-p
UIp-p
Ulp-p
dB
dB
dB
Notes
Note 1
Note 2
Note 3
Notes
Note 1
0.01-11.1 GHz
0.01-11.1 GHz
Note 2
Note 5
Note 6, 10GBd
1.25GBd
0.01-11.1 GHz
0.01-2.5 GHz
2.5-11.1 GHz
See Figure 4a

Related parts for AFCT-701SDDZ