SLCASA-CVR SOLA HEVI DUTY, SLCASA-CVR Datasheet

no-image

SLCASA-CVR

Manufacturer Part Number
SLCASA-CVR
Description
Power Supply Safety Cover
Manufacturer
SOLA HEVI DUTY
Type
Coversr
Datasheets

Specifications of SLCASA-CVR

Accessory Type
Safety Cover
Product
Linear
Commercial/medical
Commercial
Mounting Style
Panel
Open Frame/enclosed
Open Frame
Dimensions
5.62 in. L x 4.87 in. W x 2.50 in. H
Tight Regulation
0.10% Line and Load Combined
Input Voltage
100/120/220/230/240 AC Selectable
Input Frequency
47-63 Hz
Operating Temperature
0° to +50°C
For Use With
Sola Hevi-Duty SLS Series Linear Power Supply Case Style A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Silver Line Series – Single & Multi-Output Linears
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Sola
im proves on this design by offering standard screw
terminal connections and optional covers for safety
considerations.
Features
Applications
104
4
• Easy-to-install screw terminal connections
• Cover options
• Industry standard footprint
• Universal input and approvals (115/230 VAC)
• Low noise, extremely quiet DC output. For noise
• Fast transient response. Ideal for test applications.
• Built-in OVP on 5 V models and optional on
• Automatic resetting overload protection
• Short circuit protected
• Two year warranty
• Industrial control circuits and components
• Instrumentation
• Drives
• CNC machinery
• Equipment for food industry
• Microprocessor circuits
• Analog circuits
• Noise sensitive circuitry and sensors
sensitive or analog circuitry.
12, 15 and 24 V models
contact Technical Services at (800) 377-4384 with any ques tions.
Power Supplies
E137632
UL 1950
Visit our website at www.solaheviduty.com or
LVD
Specifi cations
Specifi cations are typical. Load Regulation on outputs without Remote
Sense, .1% typical.
Input Voltage
Input Frequency
Line Regulation
Load Regulation
Ripple
DC Output
Adjustment Range
Overvoltage
Protection
Transient
Response Time
Overload
Protection
Remote Sensing
Operating
Temperature Range
Storage
Temperature Range
Temperature
Coeffi cient (Typical)
Stability
Vibration
Shock
EMI/RFI
Cover Option
Cooling
Parameter
at 50% Load Changes
compensate for output
conducted and radiate
Linear power supplies
have inherently low
selected models.
Derate to 40% at
for 10% change
for 50% change
Forced air. 20 CFM required for full rating
voltage drop on
After warm-up
Method 514
Method 516
noise levels
Available to
Condition
Derate power by an additional 15%
General
+70°C
Output
Input
Derate 30% without cooling
FCC Class B and VDE
as standard (setting is
optionally available on
Automatic current limit
6.2 V ±0.4 V) OVP is
100/120/220/230/240
meet requirements of
include build-in OVP
applications they will
Per MIL-STD-810C
Per MIL-STD-810C
3.0 mV maximum
All 5-Volt outputs
For most system
0871 for class B
VAC Selectable
-25°C to +85°C
±5% Minimum
Peak-to-Peak
other types
0.01% 0°C
0 to +50°C
47-63 Hz
50 msec.
foldback
0.5 VDC
0.05%
0.05%
Limit
±.5%

SLCASA-CVR Summary of contents

Page 1

Silver Line Series – Single & Multi-Output Linears The Silver Line series follows the industry accepted footprint for open frame, linear power supplies. Sola im proves on this design by offering standard screw terminal connections and optional covers for ...

Page 2

... H2 - Case Cover Options - 1 - Catalog 1.5 A Number SLCASA-CVR SLCASB-CVR SLCASC-CVR J1 SLCASC1-CVR SLCASD-CVR J2 SLCASF-CVR Note: Covers are sold separately. When used, derate the power supply by 15% of its rated value. Visit our website at www.solaheviduty.com or Catalog Description Description Number Cover for Case A SLCASG-CVR Cover for Cases G1 and G2 ...

Page 3

Silver Line Dimensions (inches/mm) Cases C and C1 Case D AC Input Jumper Connections AC Input Jumper Connections For use at: 100 VAC 120 VAC Connect: 1-3, 2-4 1-3, 2-4 Apply AC: 1 & & 4 contact ...

Page 4

Silver Line Dimensions (inches/mm) Cases I1, I2, I3 and I4 Notes: All dimensions in inches (mm). Dimensions may change and should not be used for con struc tion purposes. Be sure to specify the complete part number when ordering. Orders ...