Specifications of FLUKE-192C/003

Scope Type
Digital Hand Held
Scope Channels
2
Bandwidth
60MHz
Meter Display Type
LCD Monochrome
Sampling Rate
500MSPS
Input Impedance
1Mohm
Rise Time
5.8ns
Input Voltage
1kV
Brand/series
ScopeMeter®/190 Series
Configuration
Handheld
Display Type
Color
Memory
3 Kpts
Sample Rate
0.5 GS/s
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
120 and 190 Series
ScopeMeter 215C,
225C and 190C Series:
Speed, performance
and analysis power
For demanding applications, the
ScopeMeter 215C, 225C and 190C
Series high-performance oscillo-
scopes offer specifications usually
found on top-end bench instru-
ments. With up to 200 MHz band-
width, 2.5 GS/s real time sampling
and a deep memory of 27,500
points per input, they’re ideal
for engineers who need the full
capabilities of a high-performance
scope in a handheld, battery pow-
ered instrument.
Dual input - 200, 100 or
60 MHz bandwidth
Up to 2.5 GS/s real time
sampling per input
ScopeMeter
incl. 225C and 215C
Bus Health Test capability for
industrial buses (225C and 215C)
High waveform resolution of
3000 datapoints per channel
Frequency Spectrum using FFT
analysis
Connect-and-View
triggering, a full range of manual
trigger modes plus external trig-
gering
Digital Persistence for analyzing
complex, dynamic signals like on
an analog oscilloscope
Fast display update rate for
seeing dynamic behavior
instantaneously
Automatic capture and replay of
100 screens
27,500 points and more per
input record length using
ScopeRecord
mode
®
automatic
Technical Data
ScopeMeter 120 Series:
Three-in-one simplicity
The compact ScopeMeter 120 Series
is the rugged solution for industrial
troubleshooting and installation
applications. It’s a truly integrated
test tool, with oscilloscope, multi-
meter and “paperless” recorder in
one affordable, easy-to-use instru-
ment. Find fast answers to problems
in machinery, instrumentation,
control and power systems.
1,000 V CAT II and 600 V
CAT III safety certified
Up to 1,000 V independently
floating isolated inputs
5000 count DMM and paperless
recorder built-in
Four hours rechargeable
NiMH battery pack
A dual input 40 MHz or 20 MHz
digital oscilloscope
Two 5,000 counts true-rms
digital multimeters
Cursor measurements
(Fluke 124, 125)
A dual input TrendPlot recorder
Connect-and-View trigger
simplicity for hands-off operation
Shielded test leads for oscillo-
scope, resistance, continuity
and capacitance measurements
Full bandwidth, VPS40 10:1
40 MHz probe included standard
with Fluke 124, 125
Up to seven hours battery
operation
600 V CAT III safety certified
Optically isolated RS-232
interface
Rugged, compact case
Bus Health test for industrial bus
systems (Fluke 125)
Power measurements and har-
monics measurement (Fluke 125)

FLUKE-192C/003 Summary of contents

Page 1

... MHz probe included standard with Fluke 124, 125 Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS-232 interface Rugged, compact case Bus Health test for industrial bus systems (Fluke 125) Power measurements and har- monics measurement (Fluke 125) ...

Page 2

... Fail testing”, Bus Health test mode (225C and 215C only), Eyepattern Display of single ended or differential bus signal (Fluke 225C and 215C only). Trigger and delay Source: Input A, input B, external trigger input. All input references isolated from each other and ...

Page 3

... Zoom Up to 16x horizontal zoom Bus health test mode (Fluke 225C and 215C only) Bus Health automatically analyzes the electrical signals on the industrial bus system to measure individual parameters and to give waveform information. Automatically compares the measurement results to preset values and present ‘good’, ‘weak’ or ’false’ ...

Page 4

... OC4USB or ® PM9080. Warranty Three-years, parts and labor on mainframe instrument One-year on accessories Accessories Standard accessories Fluke 215C, 225C and 190C Series Rechargeable battery BP190 pack (installed) Line voltage adapter/ BC190 battery charger Voltage probes and 10:1 voltage probe (VPS200, 1 red + 1 grey) including hook clip, ...

Page 5

... Horizontal Max. sample rate (both channels simultaneously): Fluke 125, 124: 2.5 GS/s for repetitive signals; 25 MS/s for single shot Fluke 123: 1.25 GS/s for repetitive signals; 25 MS/s for single shot Number of digitizers: two Time base range: 10 ns/div to 1 min/div (Fluke 125, 124) ...

Page 6

... Accuracy: ± (0 reading + 5 counts) Capacitance Ranges 500 μF Max. resolution: 5,000 counts Accuracy: ± reading + 10 counts) Other meter functions Frequency MHz (Fluke 125, 124 MHz (Fluke 123) Rotational speed (RPM): Revolutions per minute, based pulses per 2 revolutions (Fluke 125 only) Max. RPM reading: 50 kRPM Continuity: Beeper on < ...

Page 7

... FlukeView ScopeMeter software helps you get more out of your ScopeMeter: • Store instrument’s screen copies on the PC, in color (with Fluke 190C-Series only black and white • Copy screen images into your reports and documentation • Capture and store waveform data from your ScopeMeter on your PC • ...

Page 8

... Next to the above standard accessories, Fluke offers a wide range of optional accessories like temperature probes, current clamps, high voltage probes, cables, adapters and carrying cases to further assist you in your job. See the Fluke web-site or contact your dis- tributor for details. SCC190 and SCC120—Software, Case, Cable kits For user’ ...

Page 9

... Optically Isolated USB interface cable DP120 Differential Voltage Probe for Fluke 120 Series BHT190 Bus Health Test break-out adapter for DB-9, RJ-45 and M12 connection systems ITP120 Optically Isolated External Trigger Input for Fluke 120 series SW90W FlukeView ScopeMeter Software for Windows ® C190 ...

Page 10

... Web access: http://www.fluke.com ©2008 Fluke Corporation. Specifications subject to change without notice. Trademarks are the property of their respective owners. Printed in U.S.A. 12/2008 1629083 D-EN-N Rev G Modification of this document is not permitted without written permission from Fluke Corporation. Fluke 123 20 MHz 25 MS/s 1.25 GS/s 20 ns/div. ... ...