FLUKE-192C/003 Fluke, FLUKE-192C/003 Datasheet - Page 9

no-image

FLUKE-192C/003

Manufacturer Part Number
FLUKE-192C/003
Description
SCOPE METER, 60MHZ, 2 CHANNEL, 500MSPS
Manufacturer
Fluke
Type
Digitalr
Datasheet

Specifications of FLUKE-192C/003

Scope Type
Digital Hand Held
Scope Channels
2
Bandwidth
60MHz
Meter Display Type
LCD Monochrome
Sampling Rate
500MSPS
Input Impedance
1Mohm
Rise Time
5.8ns
Input Voltage
1kV
Brand/series
ScopeMeter®/190 Series
Configuration
Handheld
Display Type
Color
Memory
3 Kpts
Sample Rate
0.5 GS/s
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Fluke 225C
Fluke 225C/S
Fluke 215C
Fluke 215C/S
Fluke 199C
Fluke 199C/S
Fluke 196C
Fluke 196C/S
Fluke 192C
Fluke 192C/S
Fluke 125
Fluke 125/S
Fluke 124
Fluke 124/S
Fluke 123
Fluke 123/S
SCC190
SCC120
PM9080
OC4USB
DP120
BHT190
ITP120
SW90W
C190
C120
SCC kit includes: Hard-shell carrying case, optically isolated USB
interface cable, and FlukeView
To protect your instrument and—more importantly—
yourself, choose a test tool that can withstand the
electrical hazards present in the environment in which
you plan to use it.
ments for electrical measurement equipment. It
separates the various electrical environments into
installation categories based on the danger from
Ordering information
International safety standards
Measurement
voltage
category
CAT IV
CAT III
CAT II
CAT I
EN61010 establishes international safety require-
• Run between meter and panel
• Overhead line to detached building
• Underground line to well pump
Three-phase distribution (under 1,000 V),
including single phase commercial lighting
and distribution panels
• Feeders and short branch circuits
• Distribution panel devices
• Heavy appliance outlets with “short”
Single-phase receptable connected loads
• Outlets and long branch circuits
• All outlets at more than 10 m (30 ft)
• All outlets at more than 20 m (60 ft)
Electronic
• Electronic equipment
• Low energy equipment with transient
Summary description
Three phase at utility connection, any outdoor
conductors (under 1,000 V)
• Outside and service entrance
• Service drop from pole to building
connections to service entrance
from Category III source
from Category IV source
limiting protection
Color ScopeMeter (200 MHz/2.5 GS/s) with Bus Health Test Functions
Color ScopeMeter (200 MHz/2.5 GS/s) with Bus Health Test + SCC190
Color ScopeMeter (100 MHz/1 GS/s) with Bus Health Test Functions
Color ScopeMeter (100 MHz/1 GS/s) with Bus Health Test + SCC190 kit
Color ScopeMeter (200 MHz/2.5 GS/s)
Color ScopeMeter (200 MHz/2.5 GS/s) + SCC190
Color ScopeMeter (100 MHz/1 GS/s)
Color ScopeMeter (100 MHz/1GS/s) + SCC190
Color ScopeMeter (60 MHz/500 MS/s)
Color ScopeMeter (60 MHz/500 MS/s) + SCC190 kit
Industrial ScopeMeter (40 MHz)
Industrial ScopeMeter (40 MHz) + SCC120 kit
Industrial ScopeMeter (40 MHz)
Industrial ScopeMeter (40 MHz) + SCC120 kit
Industrial ScopeMeter (20 MHz)
Industrial ScopeMeter (20 MHz) + SCC120 kit
FlukeView
FlukeView
Optically Isolated RS-232 adapter/cable
Optically Isolated USB interface cable
Differential Voltage Probe for Fluke 120 Series
Bus Health Test break-out adapter for DB-9, RJ-45 and M12 connection systems
Optically Isolated External Trigger Input for Fluke 120 series
FlukeView
Hard Shell Carrying Case for Fluke 190 series
Hard Shell Carrying Case for Fluke 120 series
®
for Windows
®
®
®
Software + Cable + Case (190 Series)
Software + Cable + Case (120 Series)
ScopeMeter Software for Windows
®
software.
high-voltage energy transients. To choose the right
tool, the voltage rating alone does not determine the
safety. It is the combination of voltage rating and
installation category that determines maximum tran-
sient withstand capability of the tool. CAT III rated
instruments are recommended for measurement on
industrial power distribution systems.
®
ScopeMeter 215C, 225C and 190C Series, 120 Series