MSO4104B Tektronix, MSO4104B Datasheet - Page 11

no-image

MSO4104B

Manufacturer Part Number
MSO4104B
Description
OSCILLOSCOPE, 20 CHANNEL, 1GHZ, 5GSPS
Manufacturer
Tektronix
Type
Mixed Signalr
Datasheet

Specifications of MSO4104B

Scope Type
Digital Bench
Scope Channels
4 Analog + 16 Digital
Bandwidth
1GHz
Meter Display Type
XGA LCD
Sampling Rate
5GSPS
Input Impedance
1Mohm
Rise Time
350ps
Input Voltage
250Vrms
Configuration
Benchtop
Number Of Channels
4 Analog + 16 Digital
Sample Rate
5 GS/s
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Characteristics
Vertical System Analog Channels
Offset Range
Vertical System Digital Channels
Characteristic
Input Channels
Analog Bandwidth (–3 dB) 5 mV/div -
1 V/div
Calculated Rise Time 5 mV/div (typical)
Hardware Bandwidth Limits
Input Coupling
Input Impedance
Input Sensitivity, 1 MΩ
Input Sensitivity, 50 Ω
Vertical Resolution
Max Input Voltage, 1 MΩ
Max Input Voltage, 50 Ω
DC Gain Accuracy
Channel-to-Channel Isolation
Range
1 mV/div to 50 mV/div
50.5 mV/div to
99.5 mV/div
100 mV/div to 500 mV/div
505 mV/div to 995 mV/div
1 V/div to 5 V/div
5.05 V/div to 10 V/div
Characteristic
Input Channels
Thresholds
Threshold Selections
User-defined Threshold
Range
Maximum Input Voltage
Threshold Accuracy
Input Dynamic Range
Minimum Voltage Swing
Input Impedance
Probe Loading
Vertical Resolution
All MSO4000B Models
16 Digital (D15 - D0)
Per-channel Thresholds
TTL, CMOS, ECL, PECL, User Defined
±40 V
±42 V
±(100 mV + 3% of threshold setting)
30 V
10 V
400 mV
100 kΩ
3 pF
1 bit
p-p
p-p
peak
≤200 MHz
>200 MHz
±100 V
±0.5 V
1 MΩ
±10 V
±50 V
±1 V
±5 V
≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings
MSO4034B
DPO4034B
350 MHz
1 ns
±0.5 V
±10 V
50 Ω
±1 V
±5 V
±5 V
NA
Mixed Signal Oscilloscopes — MSO4000B, DPO4000B Series
±1.5%, derated at 0.10%/°C above 30 °C
300 V
Horizontal System Analog Channels
Horizontal System Digital Channels
Characteristic
Maximum Sample
Rate (All channels)
Maximum
Record Length
(All channels)
Maximum Duration
at Highest Sample
Rate (All channels)
Time Base Range
Time Base Delay
Time Range
Channel-to-Channel
Deskew Range
Time Base
Accuracy
Characteristic
Maximum Sample Rate
(Main)
Maximum Record Length
(Main)
Maximum Sample Rate
(MagniVu)
Maximum Record Length
(MagniVu)
Minimum Detectable
Pulse Width (Typical)
Channel-to-Channel
Skew (Typical)
Maximum Input Toggle
Rate
5 V
8 bits (11 bits with Hi Res)
RMS
1 MΩ ±1%, 50 Ω ±1%
20 MHz or 250 MHz
1 mV/div to 10 V/div
RMS
1 mV/div to 1 V/div
CAT II with peaks ≤ ±425 V
MSO4054B
DPO4054B
with peaks < ±20 V
500 MHz
AC, DC
700 ps
4
DPO4034B
MSO4034B
2.5 GS/s
All MSO4000B Models
500 MS/s (2 ns resolution)
20M points
16.5 GS/s (60.6 ps resolution)
10k points centered around the trigger
1 ns
200 ps
500 MHz
Maximum frequency sine wave that can accurately be
reproduced as a logic square wave. Requires the use
of a short ground extender on each channel.
This is the maximum frequency at the minimum swing
amplitude. Higher toggle rates can be achieved with
higher amplitudes.
8 ms
1 ns to 1,000 s
±5 ppm over any ≥1 ms interval
–10 divisions to 5000 s
MSO4054B
DPO4054B
20M points
2.5 GS/s
±125 ns
8 ms
MSO4104B
DPO4104B
www.tektronix.com
350 ps
1 GHz
400 ps to 1,000 s
MSO4104B
DPO4104B
5 GS/s
4 ms
11