Installation Method
Handling
Unconnected
Terminals
Tightening the Cover
3-6-6
XA-series Connectors
from J.S.T. Mfg.
Connecting External I/O for Slave Units
Connecting to Compact Connectors
1,2,3...
Contacts
Name
1. Expand the split in the sealing piece and insert the cable.
2. Place the groove on the sealing pieces onto the inside of the housing to
For terminals that are not connected, insert an NC pin into the small cable
sealing piece as shown in the following diagram. Then secure the sealing
piece onto the housing as described above.
Finally, close the cover and tighten the cover screws.
The tightening torque is 0.8 to 1.0 N·m.
The compact connectors use XA-series Connectors from JST Mfg. Co., Ltd.
Special cable connectors must be attached for cables connecting to external
devices if a Slave Unit with Compact Connectors is used.
secure it. (See following diagram.)
0.08 to 0.33
0.22 to 0.5
mm
2
Applicable cable range
28 to 22
24 to 20
AWG#
1.2 to 1.9
1.5 to 1.9
Wire sheath
diameter
external
SXA-001T-P0.6 YC692 or
SXA-01T-P0.6
Model
Section 3-6
YC692R
YRS701 to
YC701R
Crimping
Tool
113