50664 EMIT, 50664 Datasheet

Air Ionizer

50664

Manufacturer Part Number
50664
Description
Air Ionizer
Manufacturer
EMIT
Datasheet

Specifications of 50664

Ionizer Type
Overhead
Flow Rate Max
100CFM
Depth
3.5"
Width
6.5"
Height
42"
Supply Voltage Vac
115V
Peak Reflow Compatible (260 C)
No
Flow Rate
100CFM
External Width
6.50"
Supply Voltage
110V
External Depth
3.50"
External Height
42.00"
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
TB-6534 Page 1 of 8
Installation, Operation, and Adjustment
OVERHEAD ZERO VOLT IONIZER
50664/50665 (120V)
50671/50672 (220V)
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 664-9980
Instructions
Fax (909) 627-7449
DescoEMIT.com
Revision July 2008
© 2008 DESCO INDUSTRIES INC.
Employee Owned

50664 Summary of contents

Page 1

... OVERHEAD ZERO VOLT IONIZER – Installation, Operation, and Adjustment 3651 Walnut Avenue, Chino, CA 91710 TB-6534 Page Instructions Phone: (909) 664-9980 Fax (909) 627-7449 DescoEMIT.com Revision July 2008 © 2008 DESCO INDUSTRIES INC. Employee Owned ...

Page 2

... Optional network software and remote control (ZVI-IR) for adjustments are available. Installation Remove the ionizer from the carton and inspect for shipping damage. Included with the unit are: 1. 50664/50665 or 50671/50672 Overhead Ionizer 2. AC Power Cord 3. Keys (to power on) 4. Hanging Kit The AC input voltage should be set to the user’s specification prior to shipping (120v or 220v) ...

Page 3

When the ionizer is first powered on, the unit will display its default address “000”. ...

Page 4

Place the charge plate monitor under the left fan (fan 1). Press and hold the button (negative), or the zero. For finer adjustment, use single clicks of the buttons. Press the the next ...

Page 5

A The first digit of the address will be flashing. Press the first digit (0 to 2). Press the menu After pressing the display will show “OFF r” for remote off (default setting). ...

Page 6

... To remove a fan module disconnect the ribbon cable connector from the socket and lift the fan module out. The eight emitter points can be easily cleaned using Semtronics part number S204-200 emitter point cleaner, or 99% rubbing alcohol and a clean brush ...

Page 7

... Fans. • Balance 0V ±3 volt (typical), 0V ±5 volts (maximum.) • Dimensions 3-fan units: 3-1/2” 6-1/2” 42” L 2-fan units: 3-1/2” 6-1/2” 27” L • Emitter Points Machined Tungsten • Fuse 400 mA slow blow • High Voltage Power Supply 5kV • ...

Page 8

... Any unit under warranty should be shipped prepaid to the EMIT factory. Warranty replacements will take approximately two weeks. If your unit is out of warranty, EMIT will quote repair charges necessary to bring your unit up to factory standards. Call Customer Service at 909-664-9980 for proper shipping instructions and address. ...