49904 Loctite, 49904 Datasheet - Page 2

no-image

49904

Manufacturer Part Number
49904
Description
ETHYL CYANOACRYLATE ADH, TUBE, 3G
Manufacturer
Loctite
Series
499r
Datasheet

Specifications of 49904

Adhesive Type
Ethyl Cyanoacrylate
Color
Clear
Dispensing Method
Tube
Weight
3g
IDH number: 234181
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
Inhalation:
Skin contact:
Eye contact:
Ingestion:
Notes to physician:
Flash point:
Autoignition temperature:
Flammable/Explosive limits - lower:
Flammable/Explosive limits - upper:
Extinguishing media:
Special firefighting procedures:
Unusual fire or explosion hazards:
Hazardous combustion products:
Environmental precautions:
Clean-up methods:
6. ACCIDENTAL RELEASE MEASURES
5. FIRE FIGHTING MEASURES
4. FIRST AID MEASURES
Product name: 499 Super Bonder® Thermal Cycling Resistant Instant Adhesive
Move to fresh air. If symptoms persist, seek medical advice.
Do not pull bonded skin apart. Soak in warm soapy water. Gently peel apart
using a blunt instrument. If skin is burned due to the rapid generation of heat
by a large drop, seek medical attention. If lips are bonded, apply warm water
to the lips and encourage wetting and pressure from saliva in mouth. Peel or
roll lips apart. Do not pull lips apart with direct opposing force.
Immediately flush with plenty of water for at least 15 minutes. Get medical
attention. If eyelids are bonded closed, release eyelashes with warm water by
covering with a wet pad. Do not force eye open. Cyanoacrylate will bond to
eye protein and will cause a lachrymatory effect which will help to debond the
adhesive. Keep eye covered until debonding is complete, usually within 1-3
days. Medical attention should be sought in case solid particles of polymerized
cyanoacrylate trapped behind the eyelid caused abrasive damage.
Ensure breathing passages are not obstructed. The product will polymerize
rapidly and bond to the mouth making it almost impossible to swallow. Saliva
will separate any solidified product in several hours. Prevent the patient from
swallowing any separated mass.
Surgery is not necessary to separate accidentally bonded tissues. Experience
has shown that bonded tissues are best treated by passive, non-surgical first
aid. If rapid curing has caused thermal burns they should be treated
symptomatically after adhesive is removed.
80 - 93.3 °C (176°F - 199.94 °F) Tagliabue closed cup
485 °C (905°F)
Not determined
Not determined
Carbon dioxide. Foam. Dry powder. Water spray or fog.
Wear a self-contained breathing apparatus with a full face piece operated in
pressure-demand or other positive pressure mode.
None
Trace amounts of toxic and/or irritating fumes may be released and the use of
breathing apparatus is recommended.
Do not allow product to enter sewer or waterways. Ventilate area.
Do not use cloths for mopping up. Flood with water to complete polymerization
and scrape off the floor. Cured material can be disposed of as non-hazardous
waste.
personnel.