B6TS-08NF Omron, B6TS-08NF Datasheet - Page 19

Capacitance Touch Sensors Sensing IC

B6TS-08NF

Manufacturer Part Number
B6TS-08NF
Description
Capacitance Touch Sensors Sensing IC
Manufacturer
Omron
Series
-r
Type
Capacitiver
Datasheets

Specifications of B6TS-08NF

Supply Voltage
- 0.3 V to 6.5 V
Number Of Channels
8
Dimensions
9 mm L x 9 mm W x 1.7 mm H
Output Voltage
-0.3 V to Vsupply + 0.3 V
Power Dissipation
300 mW
Temperature Range
- 20 C to + 85 C
Termination Style
SMD/SMT
Sensitivity
-
Response Time
-
Interface
SPI
Channel Inputs
8 Key
Voltage - Supply
4.5 V ~ 5.5 V
Actuator Type
-
Package / Case
32-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Command code
Command code
Command code
6.2.9 BPOL: On/Off output pole (read/write enabled only in setup mode)
6.2.10
6.2.11
6.2.12
6.2.13
Command code
Command code
0x3A 1
0x3B
0x3C D15 D14 D13 D12 D11 D10
0x38
0x39
ACD: Judging count (read/write enabled only in setup mode)
CHEN: Measurement enable for each channel (read/write enabled only in setup mode)
TCAL: Teaching measurement count (read/write enabled only in setup mode)
TOG: Toggle action (read/write enabled only in setup mode)
Set the output polarity logic of On/Off output signal.
1:High Active (OUTx terminal is HIGH when touched)
0:Low Active (OUTx terminal is LOW when touched)
Only the lower-order 8 bits are valid. If the other bits are written to, they are ignored.
Enable / Disbale measurement per channel
1: measurement executed, 0: not executed
Only the lower-order 4 bits are valid. If the other bits are written to, they are ignored.
Defines the termination of the teaching algorithm if not 3 touch events per channel were found with this
time.
Only the lower-order 8 bits are valid. If the other bits are written to, they are ignored.
Selects momentary or latching output mode. This output takes effect on the signals output from OUT0 -
7 and BDATA command data.
1: Toggle mode off (momentary action: turned on only during a touch event)
0: Toggle mode on (alternate action: turned on with the first touch event and off with the next touch
event)
Only the lower-order 8 bits are valid. If the other bits are written to, they are ignored.
After ACD value + 1 consecutive measurements a touch event(or no-touch event) is judged and the
output state is changed. This takes effect on the output signals from OUT0 - 7 and BDATA command
data.
For example, with ACD = 2, after three consecutive measurements are judged as a touch event(or no-
touch event), the output state changes.
D7 - D0
D15 - D8
15
15
15
15
15
1
1
1
14
14
14
14
14
1
1
1
1
13
13
13
13
13
1
1
1
1
: ACDon (Default: 0010b)
: ACDoff (Default: 0010b)
Sets the cumulative judgment count for touch Off to On transition.
Sets the cumulative judgment count for touch On to Off transition.
12
12
12
12
12
1
1
1
1
11
11
11
11
11
1
1
1
1
10
10
10
10
10
1
1
1
1
D9
1
1
1
1
9
9
9
9
9
19
D8
1
1
8
1
8
1
8
8
8
Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0
Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0
Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0
D7
D7
7
7
7
7
7
D6
D6
6
6
6
6
6
D5
D5
5
5
5
5
5
D4
D4
4
4
4
4
4
D3
D3
3
3
3
3
3
3713050-2A Ver.080123
D2
D2
2
2
2
2
2
D1
D1
1
1
1
1
1
D0
D0
0
0
0
0
0

Related parts for B6TS-08NF