3100-40Q9999A TE Connectivity, 3100-40Q9999A Datasheet

no-image

3100-40Q9999A

Manufacturer Part Number
3100-40Q9999A
Description
RELAY CONTACTOR 30A 24VAC QC
Manufacturer
TE Connectivity
Series
3100, Products Unlimitedr
Datasheet

Specifications of 3100-40Q9999A

Contact Form
4PST-NO-DM (4 Form X)
Contact Rating (current)
30A
Switching Voltage
600VAC - Max
Turn On Voltage (max)
19.2 VAC
Turn Off Voltage (min)
6 VAC
Relay Type
Contactor
Coil Type
Non Latching
Coil Voltage
24VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
7-1611021-0
836
Features
• 4-pole contactors.
• Convenient “universal” mounting plate.
• Optional interlock/auxiliary switches available.
Contact Data @ 25°C
Material: Silver Cadmium Oxide.
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Arrangements: 4 Form X (4PST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Coil Data @ 25°C
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Contact Ratings
Dimensions are shown for
reference purposes only.
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Coil Data
Amps
Load
Full
25
30
40
Number
Poles
of
3
3
3
Voltage
240/277
240/277
240/277
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Line
480
600
480
600
480
600
6 -15
19.2
24
68
60
14
9
5
Locked
Rotor
Amps
150
125
100
180
150
120
240
200
160
20 - 70
Catalog 1308242
120
148
93
68
60
14
Issued 3-03
9
Resistive
Model 93 - 3100
Definite Purpose Contactor
4-pole, 25-40 FLA
AC Coil
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Environmental Data
Rating
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Contact Termination:
25, 30 FLA Models
40 FLA Models
Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard.
Arc Cover: Optional on 25-30 FLA models, standard on 40 FLA models.
Weight: 24 oz. (683 g) approximately
Specifications and availability
subject to change.
Amps
35
35
35
40
40
40
50
50
50
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
File E75492
File EN60947-4-1:1991
IEC 947-4-1
208/240
40 - 140
177
520
9.5
68
60
14
A 0.250” quick connect and a #6-32 screw, optional.
Voltage
110/120
200/208
240/277
110/120
200/208
240/277
110/120
200/208
240/277
480
480
480
Maximum Horsepower
50-185
277
220
750
9.5
58
52
11
Single
Phase
PRODUCTS UNLIMITED
7.5
2
5
2
5
3
-
-
-
-
-
-
series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
150 - 270
2700
480
384
48
52
11
Three
Phase
9
7.5
10
15
10
10
15
10
10
20
-
-
-

Related parts for 3100-40Q9999A

3100-40Q9999A Summary of contents

Page 1

... Nominal Sealed Nominal DC Resistance - Ohms Dimensions are shown for 836 reference purposes only. Catalog 1308242 Issued 3-03 Model 93 - 3100 Definite Purpose Contactor 4-pole, 25-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number ...

Page 2

... Ordering Information Typical Part No. 1. Series: 3100 = 4-pole, 25-40 FLA contactor 2.Packaging Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration Form X (4PST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC U = 208/240VAC H = 480VAC T = 120VAC V = 277VAC I = 24VAC, molded 5.Contact Ratings (Inductive FLA ...

Related keywords