Specifications of 3100-40Q9999A

Contact Form
4PST-NO-DM (4 Form X)
Contact Rating (current)
30A
Switching Voltage
600VAC - Max
Turn On Voltage (max)
19.2 VAC
Turn Off Voltage (min)
6 VAC
Relay Type
Contactor
Coil Type
Non Latching
Coil Voltage
24VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
7-1611021-0
Various interlock / auxiliary switches are available for the Model 93 contactor.
Auxiliary Switches
Ordering Information
Standard part numbers listed below are more likely to be available from stock.
Outline Dimensions
W/ #6-32 SCREW & SADDLE CLAMP
Dimensions are shown for
reference purposes only.
1. Series:
None at present.
2.Packaging:
3.Pole Configuration:
4.Coil Voltage (50/60 Hz.):
5.Contact Ratings (Inductive):
6.Customer ID Suffix:
7. Option Code:
3100 = 4-pole, 25-40 FLA contactor
Y = Individual Pack
- = Bulk Pack
A-ZZZ = Customer specific information (assigned by factory)
40 = 4 Form X (4PST-NO-DM)
Q = 24VAC
T = 120VAC
8 = 25 FLA
999 = Standard Model
Leave Blank = No customer-specific options
NORMALLY OPEN & CLOSED
Shown with Optional Auxiliary Switch
2.633
(66.9)
2.493
(63.3)
NORMALLY OPEN
-303 STYLE
-332 STYLE
-344 STYLE
U = 208/240VAC
V = 277VAC
9 = 30 FLA
000-998 = Factory assigned customer ID
Typical Part No.
3.055
(77 .6)
H = 480VAC
I = 24VAC, molded
10 = 40 FLA
Dimensions are in inches over
(millimeters) unless otherwise
specified.
NORMALLY CLOSED
-337 & -341 STYLE
-331 STYLE
B
SPDT
(95.25)
3.75
(82.55)
J = 120VAC, molded
K = 208/240VAC, molded
3.25
.203 TYP
(6.35)
(5.156)
.250
A - ZZ = Factory assigned customer-specific options.
3100
Catalog 1308242
Issued 3-03
(50.8)
2.00
Equipped with 0.250” (6.35) Quick Connect Terminals
Equipped with #6-32 Screw Terminals & Saddle Clamps
.203 TYP
Description
Single unit interlock
configurations listed.
Maximum of two. Must
be same polarity.
See footnote (1) for ratings.
SPDT Circuit
See footnote (2) for ratings.
SPDT Dry Circuit, 0.1 amp max.
Gold Flashed Contacts
Description
Single unit interlock
configurations listed.
Maximum of two. Must
be same polarity. (note 1)
Footnotes: Ratings of Auxiliary Interlocks / Switches
(1) Contact Rating Single Circuit NO or NC
Specifications and availability
subject to change.
(5.156)
-
and two circuit NO/NC:
Break
Make
Continuous
M = 277VAC, molded
W = 480VAC, molded
(6.35)
(79.38)
.250
3.125
40
120V 240V 480V 600V
3.0A
30A
10A
Factory Modifications
Factory Modifications
Termination Options
#10-32 Combination
ORDERING NOTE: “Standard” terminals need not be specified
in the “Ordering Information” chart above. “Special” terminals
are offered on a special order basis. Special order items may be
subject to extended leadtimes and significant minimum order
quantities. Your Tyco Electronics sales engineer must consult
with the factory before providing price and availability
information regarding items with these options.
Phillips, Slotted &
1.5A 0.75A 0.6A
15A
10A
5/16 Hex Head
Standard on
#12 Washer
25, 30 FLA
Q
7.5A
10A
Contact Config.
Contact Config.
NO
NO
1
0
1
2
0
2
1
2
1
2
1
0
1
10A
6A
9
NC
NC
0
1
1
0
2
2
1
2
1
2
0
1
1
(2) Contact Rating SPDT (337):
with Pressure
#10-32 Sems
Special on
PRODUCTS UNLIMITED
25, 30 FLA
10A, 1/3 HP , 125 or 250 VAC
1/2A, 125 VDC; 1/4A, 250 VDC:
Screw
4A 120 VAC on Lamp Load
Plate
34220-303N
34220-331N
34220-332N
34220-303N
34220-331N
34220-332N
34220-337N
34220-337N
34220-341N
34220-340N
34220-342N
34220-343N
34220-344N
Kit Catalog
Kit Catalog
Number
Number
999
Field Added Kits
Field Added Kits
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Lug accepts 14-4
Kits Required
Kits Required
Cu/Al AWG
on 40 FLA
Standard
Number of
Number of
1
1
1
2
2
2
1
2
1
1
1
1
1
(6.43)
.253
837

Related parts for 3100-40Q9999A