EVB-EMC2101 SMSC, EVB-EMC2101 Datasheet - Page 11

no-image

EVB-EMC2101

Manufacturer Part Number
EVB-EMC2101
Description
MCU, MPU & DSP Development Tools Evaluation Board
Manufacturer
SMSC
Datasheet

Specifications of EVB-EMC2101

Processor To Be Evaluated
EMC2101
Interface Type
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EVB-EMC2101 User Manual
3.10
SMSC EMC2101
Other Sensor Features
NOTE: Only one jumper is to be installed on JP11 and a minimum of one jumper must be installed
for the device to operate.
Other features such as Ideality Factor Configuration, Conversion Rate, Digital Filtering, Look-up Table
Functionality, and Standby Mode can be controlled with EMC2101 registers. See the datasheet register
description for details.
JUMPER
JP11
Table 3.6 ALERT Pull-up Resistors - SMBus/FAN MODE
NAME
5.6k
33k
18k
10k
OPEN
NA
NA
NA
NA
11
Initial FAN 100% Duty Cycle
initial FAN 100% Duty Cycle
Initial FAN 0% Duty Cycle
initial FAN 0% Duty Cycle
Auto load via EEPROM -
Auto load via EEPROM -
Host load via SMBus -
Host load via SMBus -
SHORT
Revision 1.5 (12-13-06)

Related parts for EVB-EMC2101